CDR PalmOil Tester
Innovative Analysis System for quality control of Palm Oil
PalmOilTester: the Fast, Simple & Reliable Palm Oil Analysis System.
PalmOilTester enables you to quickly determine the Acidity (FFA),Peroxide Value (PV), DOBI & Carotene Content, Iodine Value (IV) andAnisidine Value (AnV) on Palm Oil with high level of accuracy.
With its simplicity, PalmOilTester is ideal to be used during every production stages in palm oil industry to monitor the quality of oil in real time, from the oil mill to the refinery PalmOil Tester plant, during the acceptance and storage phases, as well as during trading of finished products.
Furthermore innovative PalmOil Tester features and advantages make PalmOil Tester widely used in quality control of food industries worldwide that involve palm oil ingredient.
PalmOilTester is constituted by:
- A thermostated analyzer based on photometric technology that uses solid-state emitters.
- A set of reagents prepared by CDR research laboratories Tester. Reagents are PalmOil Tester supplied in bottles with a shelf life of one year. Furthermore, plastic cuvettes are supplied.
- Pipettes with fixed calibration to PalmOil Tester ensure a correct collection of PalmOil Tester samples and an accurate dosing of reagents.
- Print Manager: software that enables the analyzer to be connected to a PC in order to store and print the results of chemical tests.
- User manual.
- Illustrated data sheets.
- DVD with filmed methods.
Test results are available in few minutes.
- Acidity (FFA) in 1 minute
- Peroxide Value (PV) in 4 minutes
- DOBI & carotene content in 6 minutes
- Iodine Value (IV) in 2 minutes
- Anisidine Value (AnV) in 2 minute
To run a test, it merely involves several simple steps.
- Add in exact amount of sample to the cuvette by using a pipette.
- Homogenize it.
- Initiate the test and result is available in few minutes.
- Results are printed by a built-in printer.
At the end of test, there is no washing of Palm Oil Tester containers, testing instrumentation or Palm Oil Tester quartz cuvettes required. No additional equipment is necessary.
As compared to official methods, it also minimizes waste, uses reagents with low toxicity and micro quantities of samples as it is.
Unlike NIR and other photometric systems, it does not require complex calibration Tester operations because it is supplied pre-calibrated. It is however possible to perform quick customized calibrations easily.
PalmOilTester owes its high sensitivity, accuracy and reliability to: photometric technology Tester that uses solid-state emitters, the digital signals processing, the possibility of aligning the system with reference standards and samples with known titration value, and the availability of reading and incubation cells thermostated at 37°C.
Several comparative studies have demonstrated Palm Oil Tester that the analytical accuracy of PalmOilTester matches that of referenced AOCS/MPOB methods, with the advantages that PalmOilTester is easier to use and outputs Tester results much faster.
PalmOilTester comes with illustrated operational sheets and filmed test methods that help the Palm Oil Testeruser to be certain about the system practicability.