HANNA Multiparameter Portable Meter HI9828/4-02

HANNA Multiparameter Portable Meter HI9828/4-02

HANNA Multiparameter Portable Meter

 

Display up to 12 parameters

·         Waterproof protection for meter (IP67) and probe (IP68)

·         Graphic LCD with backlight

·         Built-in barometer for DO compensation

·         Quick calibration feature

·         Measurement check eliminates erroneous readings

·         Auto recognition of pH and pH/ORP probe

·         Logger function records the data of all connected sensors

·         Log on demand and automatic logging (up to 60,000 samples)

·         Logged data can be displayed as graphs

·         USB for PC connectivity

·         Autorange of EC and TDS readings

·         Good Laboratory Practice feature with last 5 calibrations recorded

·         Field replaceable sensors

·         Meter accepts both alkaline and rechargeable batteries

·         Rugged probe with stainless steel tip has a diameter under 2” for wells and pipes

 

The HI 9828 multiparameter meter with GPS receiver monitors up to 13 different water quality parameters (6 measured, 7 calculated).  Measurements include pH, pH/mV, ORP, % saturation DO, mg/L DO, EC, absolute EC, resistivity, TDS, salinity, seawater specific gravity, atmospheric pressure and temperature.

The HI 9828 has a graphic, backlit LCD that automatically sizes the digits to fit the screen and allows full configuration of each parameter measured along with on-screen graphing capability. The meter incorporates comprehensive GLP features and the downloading of data via USB connection.

Each parameter is supported by on-screen context sensitive help, both in the calibration mode and during measurement.

Designed for outdoor environments, the meter is impact resistant and waterproof meeting IP67 standards (30 minutes immersion under 1 m of water). The multi-sensor probe can be left underwater in accordance with IP68 standards.

HI 769828 Multiparameter, Intelligent Probe

HANNA’s HI 769828 multiparameter probe incorporates a built-in microprocessor and amplifier that convert the high impedance signals from the sensors of the probe to eliminate common problems such as cable length limitations and noise associated with high impedance signals.

This allows the probe to have a reliable communication with the meter and also immediately warns the user of problems such as a broken cable. The standard cable lengths of the probe are 4, 10 and 20 meters (13, 32 and 64 feet) and custom lengths are also available.

The probe also features HANNA’s Quick Calibration which allows the user to calibrate pH and conductivity with one solution in a single, simple step. Dissolved oxygen is also calibrated in  one step in saturated air. The probe houses 5 of the 6 measured parameters: pH, ORP, EC,  dissolved oxygen and temperature. The sensors are all independently replaceable and are easy to maintain and keep clean. The sensors are protected by an outer PVC/stainless
steel sleeve and cap which is suitable for use in 2” wells. The probe housing complies with IP68 standard.

Sensor replacement is quick and easy with screw type connectors and color coded sensors.

The Galvanic DO sensor does not require polarization time so it’s ready at a moment’s notice.

The 4-ring conductivity system ensures stable conductivity readings that are immune to surface coating. Absolute conductivity, temperature corrected conductivity, salinity, specific gravity and TDS determinations are possible with measurements from this sensor.

The HI 9828 automatically recognizes the presence of either the pH or pH/ORP sensor.
Both sensors have a cloth junction which allows greater sensitivity, and are gel filled for improved resistance to contamination.

The meter also displays pH in mV readings—ideal for troubleshooting.

Fast Tracker™—Tag Identification System

HANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButton®s with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.

iButton® Tags are Easy to Install

Install the optional TAGs near your sampling points for quick and easy iButton® Hanna HI 9828 readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.

Choose your configuration –

HI 9828/4-01 HI 9828 and 4 m (13.1’) probe cable, no GPS, 115VAC
HI 9828/4-02 HI 9828 and 4 m (13.1’) probe cable, no GPS 230VAC
HI 9828/10-01 HI 9828 and 10 m (33’) probe cable, no GPS, 115VAC
HI 9828/10-02 HI 9828 and 10 m (33’) probe cable, no GPS, 230VAC
HI 9828/20-01 HI 9828 and 20 m (66’) probe cable, no GPS, 115VAC
HI 9828/20-02 HI 9828 and 20 m (66’) probe cable, no GPS, 230VAC
HI 9828/30-01 HI 9828 and 30 m (98’) probe cable, no GPS, 115VAC
HI 9828/30-02 HI 9828 and 30 m (98’) probe cable, no GPS, 230VAC
HI 9828/40-01 HI 9828 and 40 m (131’) probe cable, no GPS, 115VAC
HI 9828/40-02 HI 9828 and 40 m (131’) probe cable, no GPS, 230VAC
HI 9828/50-01 HI 9828 and 50 m (164’) probe cable, no GPS, 115VAC
HI 9828/50-02 HI 9828 and 50 m (164’) probe cable, no GPS, 230VAC
HI 9828/60-01 HI 9828 and 60 m (200’) probe cable, no GPS, 115VAC
HI 9828/60-02 HI 9828 and 60 m (200’) probe cable, no GPS, 230VAC
HI 9828/70-01 HI 9828 and 70 m (230’) probe cable, no GPS, 115VAC
HI 9828/70-02 HI 9828 and 70 m (230’) probe cable, no GPS, 230VAC
HI 9828/80-01 HI 9828 and 80 m (262’) probe cable, no GPS, 115VAC
HI 9828/80-02 HI 9828 and 80 m (262’) probe cable, no GPS, 230VAC
HI 9828/90-01 HI 9828 and 90 m (295’) probe cable, no GPS, 115VAC
HI 9828/90-02 HI 9828 and 90 m (295’) probe cable, no GPS, 230VAC
HI 9828/100-01 HI 9828 and 100 m (328’) probe cable, no GPS, 115VAC
HI 9828/100-02 HI 9828 and 100 m (328’) probe cable, no GPS, 230VAC

 

Order Information:
HI 9828 configurations are supplied with HI 769828 multisensor probe (pH/ORP, EC, DO, temperature), HI 9828-25 quick calibration standard solution (500 mL), probe maintenance kit, rechargeable C size Ni-MH batteries (4), power adapter & cable, car 12V accessory outlet adapter, HI 7698281 USB interface cable, HI 92828 Windows® compatible software and instruction manual in a rugged carrying case.

pH Range 0.00 to 14.00 pH
Resolution 0.01 pH
Accuracy ±0.02 pH
mV of pH Input Range ±600.0 mV
Resolution 0.1 mV
Accuracy ±0.5 mV
ORP Range ±2000.0 mV
Resolution 0.1 mV
Accuracy ±1.0 mV
Dissolved
Oxygen
Range 0.0 to 500.0% / 0.00 to 50.00 mg/L
Resolution 0.1% / 0.01 mg/L
Accuracy 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 mg/L: ±1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ±3% of reading
Conductivity Range 0.000 to 200.000 mS/cm (absolute EC up to 400 mS/cm)
Resolution manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm ; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
Accuracy ±1% of reading or ±1 µS/cm whichever is greater
Resistivity Range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resolution dependent on resistivity reading
TDS Range 0 to 400000 mg/L or ppm (the maximum value depends on the TDS factor)
Resolution manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt); autorange scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); autorange g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)
Accuracy ±1% of reading or ±1 mg/L (ppm) whichever is greater
Salinity Range 0.00 to 70.00 PSU (Extended Practical Salinity Scale)
Resolution 0.01 PSU
Accuracy ±2% of reading or 0.01 PSU whichever is greater
Seawater
Specific
Gravity
Range 0.0 to 50.0 σt, σ0, σ15
Resolution 0.1 st, s0, s15
Accuracy ±1 σt, σ0, σ15
Atm. Pressure Range 450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Resolution 0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Accuracy ±3 mmHg within ±15°C from the calibration temperature
Temperature Range -5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K
Resolution 0.01°C; 0.01°F; 0.01K
Accuracy ±0.15°C; ±0.27°F; ±0.15K
Calibration pH automatic one, two, or three points with five memorized standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
ORP automatic at one custom point
Conductivity automatic one point with six memorized standards (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
DO automatic one or two points at 0, 100% or one custom point
Resistivity, TDS, σ based on conductivity or salinity calibration
Salinity one custom point
Atm. Pressure,
Temperature
automatic at one custom point
Temperature
Compensation
automatic from -5 to 55°C (23 to 131°F)
Logging Memory up to 60,000 samples with 13 measurements each
Logging Interval 1 second to 3 hours
Computer
Interface
USB (with HI 929829 software)
Waterproof
Protection
meter IP67, probe IP68
Environment 0 to 50°C (32 to 122°F); RH 100%
Power Supply 1.5V alkaline C cells (approximately 150 hours of continuous use without backlight) (4) / 1.2V rechargeable C cells (approximately 70 hours of continuous use without backlight) (4)

 

 

 

Shimadzu Moisture Balance

Shimadzu Moisture Balance

Shimadzu Moisture Balance

UniBloc Moisture Analyzer MOC63u

In many fields, a moisture analyzer is a necessary tool for quality control requirements. With the MOC63u, you can easily obtain accurate data. Simply place material on the pan and shut the cover. The MOC63u will start to measure. The MOC63u adapts to various materials and increases your work efficiency.

Halogen heater

Shimadzu Moisture Balance long-life and high power halogen heater provides quick and accurate measurement.
The temperature can be changed from 50 degrees to 200 degree Celsius.
You can check sample status from window while measurement.

Large pan size: 95mm dia

Shimadzu Moisture Balance MOC63u has large pwn. (95mm diameter)
It can provide quick and accurate measurement to spread sample in thin layer on the pan.

Data management and easy operation

Built-in USB port

UniBloc technology
The measure results can be transferred by USB cable.
If connect with PC by USB, needs USB driver.
Please download from here.

WindowsDirect

Send balance data to Excel or other Windows applications without installing additional data communication software. By combining standard Auto print functions with typical spreadsheet functions, even difficult applications can be easily automated.You can create graphs easily with WindowsDirect and Excel.
If you need templates, please download from here.
Connection to Windows Vista and Windows7.

Easy operation using a simple keypad

Shimadzu Moisture Balance features easy-to-operate software and keypad layout. In addition, an automatic starting mode saves measurement time, increasing your work efficiency. Operation simply requires ‘putting material on the pan and shutting the cover’. Internal memory can save 10 measurement conditions and 100 results. Various measurement modes provide extra support.

Various measurement modes

Ending modes:

Automatic ending mode

Automatic ending mode
Automatically ends measurement when moisture loss over the previous 30 seconds Shimadzu Moisture Balance becomes smaller than specified percentage.

Timed ending mode

Timed ending mode
Automatically ends measurement when the specified amount of time has elapsed.
Alternative drying modes:

Rapid drying mode

Rapid drying mode
First dries with the highest temperature for the specified period, then shifts to the specified temperature, Shimadzu Moisture Balance shortening measurement time.

Slow drying mode

Slow drying mode
Gently heats samples that might solidify at the surface or samples that reduce under high temperature.

Step drying mode

Step drying mode
Allows step-by-step change in drying conditions. This feature is useful when measuring samples that contain a large amount of water.
Starting mode:

Automatic starting mode

Shimadzu Moisture Balance starts measurement immediately after closing the lid. It saves time in repeat measurements.

HANNA Research Grade Meter with Calibration Check

HANNA Research Grade Meter with Calibration Check

pH/ORP/ISE & Resistivity/Salinity & Temperature

HANNA Research Grade Meter with Calibration Check

  • Two input channels (pH/ORP/ISE)
  • pH Calibration Check™
  • Five point pH and ISE calibration with standard and custom buffers
  • Fully customizable
  • GLP features
  • Large log memory with different logging methods

 

HI 4222 is a research grade pH, ORP and temperature benchtop meter. This instrument incorporates dual channels with a separate temperature input and support the external reference electrodes required by some pH and ISE sensors.

The customizable user interface can display two channels at the same time, showing the measurements in various modes: basic measurement with or without GLP information, graph or log history.

These instruments Hanna offer multi-language support and contextual help is available through a dedicated Help key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through all measurement and calibration procedures to ensure measurements and procedures are performed properly.

HANNA’s pH Calibration Check™ diagnostics system ensures accurate readings every time by alerting users of potential problems during the calibration process. The Calibration Check™ system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions. After the guided calibration process, an electrode condition indicator is displayed on the LCD informing the user of the overall pH electrode status.

Automatic, semiautomatic and manual pH calibration is available in up to five points, with eight standard (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) and up to 5 custom buffers. The Out of Calibration Range and Cal Due features alert the user in the event the measurement is far from the calibration point or when the meter is due for recalibration. Proper, scheduled calibrations are crucial for accurate and repeatable measurements.

This instrument also features up to five point Manual Selection and Custom Standard ISE calibration. From the on-screen list, users can select their ISE electrode parameter along with it’s standard configuration profile or create their own.

Up to a four point automatic or custom standard conductivity calibration can be performed in up to four points as well as probe cell constant

Up to 10 profiles can be saved and recalled, eliminating the need to reconfigure each time when a different electrode is used. User definable configurations can include: temperature compensation in accordance with each parameter, ISO-potential points for pH and ISE, measurement units of ISE concentrations and ISE electrode type, temperature units. Three selectable logging modes are available: HAnna Automatic, Manual and AutoHold logging. Up to 100 logging lots can be stored for automatic or manual modes along with up to 200 USP reports, and up to 100 ISE methods reports. Automatic logging features a selectable area and sampling period while GLP information includes complete data about user calibration of each parameter and identification information for the instrument, user, and company. Data can be transferred to a PC via the opto-isolated PC interface via the RS232 or USB ports and HI 92000 software (optional).

 

pH Range -2.000 to 20.000 pH
Resolution 0.1 pH; 0.01 pH; 0.001 pH
Accuracy ±0.1 pH; ±0.01 pH; ±0.002 pH ±1 LSD
mV Range ±2000 mV
Resolution 0.1 mV
Accuracy ±0.2 mV ±1 LSD
ISE Range 1 x 10-6 to 9.99 x 1010 concentration
Resolution 1; 0.1; 0.01; 0.001 concentration
Accuracy ±0.5% (monovalent ions); ±1% (divalent ions)
Temperature Range -20.0 to 120°C; -4.0 to 248.0°F; 253.15 to 393.15K
Resolution 0.1°C; 0.1°F; 0.1K
Accuracy ±0.2°C; ±0.4°F; ±0.2K (without probe)
Calibration pH automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01,9.18, 10.01, 12.45), and five custom buffers
ISE automatic, up to five point calibration, 5 fixed standard solutions available for each measurement unit, and 5 user defined standards
pH Calibration Check™ yes
Rel. mV Offset Range ±2000 mV
Input Channel(s) 2 pH/ORP/ISE
GLP cell constant, reference temperature/coefficient, calibration points, cal time stamp
pH Temp. Compensation automatic or manual from -20.0 to 120.0°C/-4.0 to 248.0°/253 to 393K
pH Electrode HI 1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe HI 7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)
Logging Record 100 lots with 10,000 record/lot
Interval settable between 1 and max log time
Type automatic, log on demand, auto HOLD
Display 240 x 320 dot-matrix color LCD with on-screen help, graphing, language selection and custom configuration
PC Connection / Power Supply USB and RS232 / 12 VDC adapter (included)
Environment / Dimensions / Weight 0-50ºC (32 to 122ºF) (273 to 323K) RH max 95% non-condensing / 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) / 1.2 Kg (1.8 lbs.)

Shimadzu UV-1800

Shimadzu UV-1800

UV-VIS Spectrophotometers

UV-1800

Designed in accordance with the governing Japanese and European Pharmacopoeia, the new UV-1800 UV-VIS spectrophotometer achieves a resolution of 1 nm, the highest in its class, in a compact design. Offering an array of user-friendly features, the UV-1800 can be used as either a stand-alone or as a PC-controlled instrument.

Features

UV-1800 high resolutionHigh resolution 
Featuring the highest resolution in its class* (1 nm), the UV-1800 easily satisfies the standards of wavelength resolution demanded by the European Pharmacopoeia. Additionally, using a blazed, holographic grating with a Czerny-Turner mount results in a compact, high-throughput optical system. Stray light, wavelength repeatability and baseline stability have also been advanced to meet user requirements.
(*As of March 2007, according to Shimadzu research.)

UV-1800 compactnessCompact
Only 450 mm wide, the UV-1800 is one of the most compact instruments in its class, allowing installation in tight spaces. In comparison to the UV-1700, the required space has decreased by about 15%, and the width has narrowed by about 20%.

User Friendly 
USB memory can be connected directly to the UV-1800. Users can now analyze data on a PC using UVProbe software. In addition, data for spectra and time-course curves can be displayed and saved with commercial spreadsheet software. Printing is possible to printers that support PCL control codes, e.g:

  • HP Business Inkjet 1200
  • HP Photosmart D5160

Using UVProbe software, provided standard with this instrument, makes it possible to control the UV-1800 with a PC. (A USB cable is required for connection to the PC.)

UV-1800 with PC

Security functions

Enabling the UV-1800 security functions makes it possible to restrict functions according to the user level.

Instrument validation functions

The UV-1800 offers compatibility with 9 JIS items. Wavelength accuracy, wavelength repeatability, resolution, stray light, photometric accuracy, photometric repeatability, baseline flatness, baseline stability, noise level.

Maintenance

The operating time of the deuterium (D2) lamp and the halogen (WI) lamp can be recorded and displayed. Consequently, the expected replacement period of the lamps can be ascertained when performing periodic inspections, minimizing downtime.

Measuring Modes

Equipped with a variety of measurement modes as standard in a stand-alone instrument, the UV-1800 enables you to perform a range of applications, including photometrics and protein quantitation.

Photometric Mode

Measures the absorbance or transmittance at a single wavelength or at multiple (up to eight) wavelengths. In multiple-wavelength measurement, calculations can be performed on the data obtained for up to four wavelengths, including the calculation of the difference between, or ratio of, the measurements obtained for two wavelengths.

Spectrum Mode

Obtains sample spectra using wavelength scanning. Changes in the sample can be tracked using repeated scans. Data processing operations, such as the enlargement or reduction of the spectra obtained, peak detection, and area calculations, are also possible.

Spectrum Mode

Quantitation Mode

Generates a calibration curve from standard samples, and uses it to calculate the concentrations of unknown samples. Various combinations of wavelengths (1 to 3 wavelengths and derivatives) and calibration curves (K-factor and first-to-third order regression calibration curves) are possible.

Quantitation Mode

Kinetics Mode

Measures the change in absorbance as a function of time, and thereby obtains enzymatic activity values. The kinetics measurement method or the rate measurement method can be selected. Using this mode in combination with an MMC-1600/1600C multi-cell holder (8/16 series multi-cell) or a CPS-240A cell positioner (6 cells) enables the consecutive analysis of multiple samples.

Kinetics Mode

Biomethod Mode (provided as standard)

Capable of analyzing DNA and proteins using the following quantitation methods.

  • Nucleic Acid Quantitation- Quantitates DNA or protein using the absorbance at 260/230 nm or 260/280 nm.
  • Protein Quantitation
  • Lowry method
  • BCA method (using bicinchoninic acid)
  • CBB method (using Coomassie Brilliant Blue G-250)
  • Biuret method
  • UV absorption method (direct measurement at 280 nm)

 

Specifications

 

Wavelength range 190 to 1100nm
Spectral bandwidth 1nm (190 to 1100nm)
Wavelength display 0.1-nm increments
Wavelength setting 0.1-nm increments (1-nm increments when setting scanning range )
Wavelength accuracy ±0.1nm @ 656.1nm D2
±0.3nm (190 to 1100nm)
Wavelength repeatability ±0.1nm
Stray light less than 0.02% NaI @ 220nm, NaNO2 @ 340nm
less than 1.0% KCl @ 198nm
Photometric system Double Beam
Photometric range Absorbance: -4 to 4 Abs
Transmittance: 0% to 400%
Photometric accuarcy ±0.002 Abs (0.5Abs)
±0.004 Abs (1.0Abs)
±0.006 Abs (2.0Abs)
Photometric repeatability less than ±0.001 Abs (0.5Abs)
less than ±0.001 Abs (1Abs)
less than ±0.003 Abs (2.0Abs)
Baseline stability less than 0.0003 Abs/H @700nm
(one hour after light source turned ON)
Baseline flatness within ±0.0006 Abs
(190 to 1100nm,one hour after light source turned ON)
Noise level within 0.00005 Abs RMS value (@700nm)
Dimensions (W×D×H) 450(W) x 490(D) x 270(H)
Weight 15kg
Printers DPU, ESC/P, PCL printers, USB I/F Windows-compliant printers are available with USB memory and PC software
Memory USB memory (option) Saved as text and UVPC file
Performance for PC USB memory + UVProbe (standard) Win XP

Skalar San++

Skalar San++

San<sup>++</sup>

Overview

The Skalar San++ Automated Wet Chemistry Analyzer also known as Continuous Flow Analyzer has been designed as a modular system to meet the needs of laboratories which process a few samples or large volumes of samples. Based on the Continuous Flow Analysis (CFA) or also called Segemented Flow Analysis (SFA) technique, up to 16 analytical measurements can be made on a single sample simultaneously. With the addition of rinsing valves and software the San++ system can automate; start-up, shut-down, dilutions, reruns, clean-up, and raw data storage.

Skalar, the world leader in wet chemistry technology offers, over 300 proven applications utilizing various combinations of automatic dilutions, additions, mixing, heating, dialysis, extractions, distillation, digestion, phase-separation, hydrolysis, ion-exchange/reduction and more. Skalar has developed a proven systematic approach to providing a quality system starting with complete applications engineered on customer samples to provide the best possible configuration to the customer needs and requirements, training and installation by qualified specialists and complete application and service support.

Samplers

The Skalar range of San++ samplers offers for each routine laboratory and application the perfect match saving operators time and errors. With the unique automatic standard preparation and over range dilution facility, high workloads are fully automatically analyzed outside working hours, without any operator supervision.

Skalar Samplers offer the highest degree of automation available today with:

  • Real Automatic pre- and post dilution runs
  • Full automatic standard preparation
  • Random access
  • Automatic multiple range operation
  • Built in rinse pump
  • Customized sample containers and racks
  • Automatic bar-code reader
  • Multiple sample probes
  • Extended operation outside working hours with automatic start up and shut down
  • Full analyzer control
1100/1150 Sampler
1150 Sampler The SA1100 and SA1150 samplers accommodate up to 2 x 50 sample positions, with built in rinse pump. Optionally, 10 dedicated standard positions are available for working standards. Furthermore, they can be equipped with a second needle for dual needle sample pick-up and extended sample positions (up to 100 positions). The samplers are random access and computer controlled, the SA 1150 sampler is extended with a soft keypad to run in or computer or manual control mode.
1050 Sampler
1050 Sampler Computer controlled RØZ sampler, series 1050, for up to 140 samples with separated standard and QC sample positions, built in rinse pump, optional automatic diluter station for automatic pre- and post run dilutions, and automatic standard preparation, with optional dual sample pick up (SA 1053) and optional stirrer.
1074 Sampler
1074 Sampler Computer controlled XYZ sampler series 1074, for 300 samples, with separate positions for standards and QC samples, with container volumes of 35 mL. Build in rinsing pump. Optional automatic diluter station for automatic pre- and post run dilutions and automatic standard preparation, Extendable with 2 to 4 needles for simultaneous sample pick up with different matrices, with optional stirrer and automatic bar code reader and customized sampler container racks also available with larger footprint for more then 300 samples.
1075 Sampler
1075 Sampler The SA1075 Random Access auto sampler carries standard 540 sample positions, divided over 9 racks of 60 samples each. In addition, there are 26 positions available in a separate tray for working standards, QC samples and drift control samples, with container volumes of 35 ml. Extendable with 2 to 4 needles for simultaneous sample pick up with different matrices. Optional automatic diluter station for automatic pre- and post run dilutions and automatic standard preparation.

Chemistry Section

The unique concept of the chemistry section has proven its performance for hundreds of applications, with maximum operator convenience and lowest routine maintenance. The latest developments in Continuous Flow Analysis (CFA) have been integrated into the chemistry modules.
The throughput of the analyzer depends upon application and can vary from 25 to 120 analyses per hour. Complex manipulations such as distillation, in-line UV digestion, extraction, etc. are incorporated on the chemistry modules.

  • Robust unique double radius pump deck for accurate dosing with up to 2x 16 pump tubes.
  • 2 separated pump decks for 2 x 2 channel concept.
  • Controlled synchronized 10 channel air injection with separated build-in compressor for increased flow stability and fast start up.
  • Easy access to chemistry modules with flexible ultra low carry-over connections between dialyzers, reactors, coils, flow cells and other components.
  • Leak detection
  • 3 – Cuffs long life pump tubes.
  • Manual operated and automatic software controlled rinsing valves for easy automatic start up and overnight operation.

The Chemistry section is compact and easy to handle. It houses up to 5 chemistry modules with build in robust dosing pump and air injection system, up to 5 easy interchangeable modules with build in photometric detectors and 5 separated waste receptacles.

Detectors

The Skalar San++ range of detectors comprises digital dual channel colorimetric detectors, the unique digital matrix correction detector with automatic background correction for specific sample matrixes, but also covers a range of detectors for I.R., UV, Fluorimetry, ISE, Flame Photometry, pH meter, Density meters, etc. The Skalar range of detectors covers all detectors required for the hundreds of Skalar field tested SFA applications available today.

Special features of the detectors for the San++ Continuous Flow Analyzer (CFA) are:

  • Compact design and software controllable
  • Allows the implementation of bubble gating
  • Easy access and no alignment of robust flow cells
  • Increased stability, sensitivity and auto-scaling by digital detectors
  • Automatic matrix and blank correction
  • Wide linear measuring range

Software

The San++ FlowAccess™ V3 data acquisition Windows® software package controls the complete analyzer, with auto start-up and shut down, hardware functions control, detector auto-scaling, pre-and post run sample dilutions, result calculation and statistics. 1 to 16 channels, with multiple samplers and multiple needles are handled simultaneous. Each chemistry can be grouped for analysis. As of it GUI the package is extremely users friendly and easy to operate, and will integrate easily into a network.

The FlowAccess™ V3 software package has a flexible sample table layout, with auto numbering and editing during analysis run. Sample ID.’s can also be imported from LIMS or read by the automatic bar code reader.

SoftwareFlow Access has preset QC. criteria, with real time peak and result information on screen, with zooming and rescaling and real time peak editing. All raw data is stored on file for validation and re-analysis.

Typical Applications

The Skalar San++ Analyzers are operating worldwide for hundreds of different applications. It is for decades the reliable “workhorse” for many routine laboratories; analyzing waters, soils, fertilizer, detergents, tobacco, pharmaceuticals, food and beverages such as beer, wine, milk, etc. Skalar methods meet standard methodology whenever possible, such as EPA, ASTM, ISO, AOAC, Standard Methods, EBC, Coresta, etc., etc. and are tested in our well equipped application laboratory. Skalar San++ Analyzers are supplied with detailed method description of reagent make up, flow diagram and any information required running a specific application trouble free for many years.

The amount of available Continuous Flow Analysis applications is nearly unlimited; popular ones are listed below:

Acetaldehyde Density Nitrogen (TKN)
Acetic Acid Diacetyl Dissolved Organic Carbon
Total Acidity Digoxin Penicillin
Total Alkalinity Enzyme Activity Perborate
Aluminium Ethanol pH
Amino Acids Fluoride Phenol
Free Amino Nitrogen Formaldehyde Total UV digestable Phosphate
Ammonia Formic Acid Phosphate (ortho/total)
Amylase Fructose Polyphenols
Amylose Galactose Potassium
Anionic Surfactants Glucose Total UV digestable Nitrogen
Ascorbic Acid L-Glutamic Acid Protein
Benzoic Acid Glycerol Pyruvate
Total Bicarbonate Total Hardness (Total) Reducing Sugars
Bitterness Hydrazine Riboflavin
Boron Hydrogen Sulphide Silicate
Bromide Hydroxymethylfurfural Sodium
Caffeine Hydroxyproline Sorbitol
Calcium Iodine Starch
Calcium pantothenate Iron Sucrose
Carbohydrate L-D-Lactic Acid Sulfate
Carbon Lactose Sulfite
Citric Acid Magnesium Sulfur Dioxide (free/total)
Chloride L-Malic Acid Tartaric Acid
Chlorine Maltose Thiamine
Cholesterol Manganese Urea
Cholinesterase Inhibition Methanol Volatile Acidity
Chromium Methanamine Zinc
Cobalt Niacinamide And many more…
Color Nickel
Copper Nicotinic Acid
Creatine Nitrate
Cyanide Nitrite