Euromex Oxion Series Microscopes from Holland

Euromex Oxion series

Euromex Oxion series

The Oxion series has been specifically designed for the Exact- and Biomedical Sciences

Thanks to the high resolving power, a 3 Watt transmitted LED illumination, a 100 Watt Mercury fluorescence epi-illumination, multiple phase contrast, dark field set and the optional Apochromatic objectives, these microscopes can be used for all kind of demanding applications as well in fundamental research

  • Wide Field eyepieces HWF 10x / 22
  • Semi Plan SMP 4x, 10x, S40x and S100x-oil objectives for bright field contrast
  • Plan PL 4x, 10x, 20x, S40x, S60x and S100x-oil objectives for bright field contrast
  • Plan Phase PLPH 10x, 20x, S40x and S100x-oil objectivesfor phase contrast
  • Plan Semi-Apochromatic PL APO 4x, 10x, 20x, S40x and S100x-oil objectives for bright field contrast
  • Plan Semi-Apochromatic PL APO FLUAREX 4x, 10x, 20x, S40x and S100x-oil objectives for fluorescence
  • Binocular withor without photo port
  • Height adjustable Abbe condenser N.A. 1.25 with holder for phase sliders
  • Zernike phase and bright field disc condenser with 4 phase rings
  • Zernike phase and bright field disc condenser with 3 phase rings + dark field stop
  • Cardioid dark field Oil-immersion condenser with built-in 5 W LED illumination
  • Large stage with ball beared XY translation stage with optional heating elements and temperature controller
  • Adjustable 3 Watt LED illumination
  • 100 Watt mercury vapor lamp for fluorescence
  • Many fluorphore filter sets available

Models OX.3012 and OX.3015 are equiped with standard Semi Plan objectives for bright field applications
Models OX.3020 to OX.3035 are equiped with standard Plan objectives for bright field applications
Models OX.3040 to OX.3047 are equiped with Plan Phase objectives for phase contrast
Models OX.3050 to OX.3065 are equiped with Plan Semi-Apochromatic objectivesfor bright field applications
Models OX.3070 to OX.3085 are equiped witht Plan Semi-Apochromatic objectives for fluorescence applications
Model OX.3064 is equipped with standard Plan objectives and a cardioid oil-immersion condenser with built-in 5 W LED illumination for dark field applications and living blood analysis

TOMY AUTOCLAVES SPEEDY SX-SERIES FROM JAPAN

TOMY AUTOCLAVES, SPEEDY SX-SERIES FROM JAPAN

Autoclaves SX series LineUP

    • SX-300
    • SX-500
    • SX-700

    • SX-300E
    • SX-500E
    • SX-700E

Accessories here

Speedy Autoclaves

Maximized chamber capacity at Minimum installation space

Easy operation using the “Top-open lid”

A top-open lid, which can be operated easily with a single hand or foot, is provided with the SX autoclaves. To open the lid, the lid lock is released by stepping on the foot pedal locates at the bottom while pressing the lid down. The lid can be opened with minimal effort owing to mechanical assistance. In addition, the lid can be closed easily just by pressing it down.

Saving the installation space

The main body is very compact owing to the design which provides thorough installation space saving. In addition, installation space at the side of the main body which is required for models employing a slide-open lid, which is not necessary at SX autoclaves top-open lid. Even when several SX autoclaves are installed side-by-side, the necessary installation space is minimized.

A : 790mm(SX-300),970mm(SX-500),1003mm(SX-700)
B : 614mm(SX-300),794mm(SX-500),827mm(SX-700)
C : 410mm(SX-300/500),470mm(SX-700)

Easily viewable “work monitor”

The LED display shows working status for easy monitoring. The process being performed is indicated by an LED indication lamp blinking in red.

The illuminated display on the operating panel shown in the picture is different from the actual display at the time of operation.

Cooling fan provided as a standard feature

A rapid air-cooling function (vessel-cooling fan) permitting reduction of chamber cool down time is provided as a standard feature. This is most appropriate for lowering the temperature rapidly on completion of the cycle. The time required for lower the temperature is much reduced by employment of the cooling fan in comparison with natural cooling.

Sterilizing course selection

The optimal sterilizing course can be selected from among five courses, such as the liquid sterilizing course in addition to that for normal sterilization.

Other features

Large indication lamp “Operated”

An easily viewable large indication “Operated” is provided at the upper section of the operating panel.
Depending on the pressure status (normal pressure/pressure is applied),the displayed color changes.

Setting to 100°C is possible.

Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).

Auto-variable exhaust speed

A function allowing the exhaust valve to open automatically after completion of sterilization is provided. The exhaust speed can be set to one of six levels (set to variable for liquid sterilization)

Timer function

The operation starting time can be preset easily. By presetting the start of operation, otherwise wasted periods at night or early morning, can be used effectively.

Setting to 100°C is possible.

Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).

Lid interlock

A safety device (lid interlock mechanism) for locking the lid during operation is provided. A high level of safety is assured to prevent unanticipated accidents.

Pressure fine adjustment function

When the balance between the temperature and pressure deviates during sterilization, fine exhausting is carried out automatically in order to adjust the best chamber condition.

Functions & Features
Liquid sterilizing / Heating / Warming / Check / Last-run memory / Built-in steam exhaust bottle
Flat internal surface of the chamber / Lid opening/closing detection mechanism
Exhaust bottle detection mechanism / Leakage breaker provided

OPTION

External sensor for the articles to be sterilized

被滅菌センサSensor for directly detecting the temperature of articles to be sterilized. More reliable sterilization monitor can be carried out.

Data output

データ出力The temperature data, pressure data, etc. can be exported. The temperature can be recorded when the external recorder is connected.

External sensor and recorder

外部センサ・記録計A temperature sensor and recorder independent of the autoclaves. The chamber temperature can be recorded.

SX Specifications

Model name SX-300 SX-500 SX-700
Operating temperature range Sterilizing 105 ∼ 135°C(0.019 ∼ 0.212MPa)
Heating 45 ∼ 104°C(0 ∼ 0.015MPa)
Warming 45 ∼ 95°C
Maximum operating pressure 0.263MPa 0.25MPa
Temperature Display Digital
Pressure gauge Display Analog
Display range 0 ∼ 0.4MPa
Heat source 1.5kW electric heater 2kW electric heater 3kW electric heater
Safety device • Water level sensor, • Current leakage breaker, • Lid interlock, • Over-heat prevention, • Over-pressure prevention, • Open temperature sensor detection, • Safety valve
Time Display Digital
Display
range
Sterilizing 0:00 – 9:59, 0 – 99hours, 0 – 999min.(0:00 – 9:59,10 – 99hours changeable)
Heating
Warming Variable: 0 – 99hours
Chamber dimensions φ325 x 553mm φ325 x 733mm φ370 x 774mm
Chamber capacity Effective internal
volume:36L,
Internal volume:44L
Effective internal
volume:50L,
Internal volume:58L
Effective internal
volume:69L,
Internal volume:79L
Chamber material SUS304
Dimensions (mm) 410W x 477D x 790Hmm
(With protruding:574D)
410W x 477D x 970Hmm
(With protruding:574D)
470W x 528D x 1003Hmm
(With protruding:625D)
Weight 50kg 60kg 72kg
Rated voltage 120V AC
230V AC
Power input 13A/120V 17A/120V
7A/230V 9A/230V 13A/230V
Required power supply Single-phase 120V AC
(50/60 Hz)15A or more
Single-phase 120V AC
(50/60 Hz)20A or more
Single-phase 230V AC
(50/60 Hz)10A or more
Single-phase 230V AC
(50/60 Hz)15A or more
Single-phase 230V AC
(50/60 Hz)15 A or more
Power consumption (calorific value) 1.5kW (1290kcal/h) 2.0kW (1720cal/h) 3.0kW (2580cal/h)
Environmental Conditions When opereting the autoclave, observe the environmental conditions given below.
Ambient temperature: 10 to 35°C
Almospheric pressure: 860 to 1060hPa
Relative humidity: 30 to 85%
Maximum gradient: 2
Accessories Stainless baskets 1
(φ300 x 182mm)
Stainless baskets 2
(φ300 x 182mm)
Stainless baskets 2
(φ345 x 181mm)
• Chanber bottom Plate 1, • Caster stoppers 4, • Operator’s Manual 1, • Clear folder (for storing the operation manual) 1, • Screw (for attaching the clear folder) 1, • Warranty card 1, • Customer card 1, • Inspection Sheet 1

SX-E Specifications

Model name SX-300E SX-500E SX-700E
Operating temperature range Sterilizing 105 ∼ 135°C (0.019 ∼ 0.212MPa)
Heating 45 ∼ 104°C (0 ∼ 0.015MPa)
Warming 45 ∼ 95°C
Maximum operating pressure 0.263MPa 0.25MPa
Temperature Display Digital
Pressure gauge Display Analog
Display range 0 – 0.4MPa
Heat source 1.5kW electric heater 2.0kW electric heater 3.0kW electric heater
Safety device • Water level sensor, • Leakage breaker, • Lid interlock, • Over-heat prevention, • Over-pressure prevention, • Temperature sensor break detection, • Safety valve
Protection type against electrical shock Class I equipment
Time Display Digital
Display
range
Sterilizing 0:00 – 9:59, 0 – 99hours, 0 – 999min.(0:00 – 9:59,10 – 99hours changeable)
Heating
Warming Variable: 0 – 99hours
Pressure chamber type PED Category II
Chamber dimensions φ325 x 553mm φ325 x 733mm φ370 x 774mm
Chamber capacity Effective internal
volume:36L,
Internal volume:44L
Effective internal
volume:50L,
Internal volume:58L
Effective internal
volume:69L,
Internal volume:79L
Chamber material SUS304
Dimensions (mm) 410W x 477D x 790Hmm
(With projection:574D)
410W x 477D x 970Hmm
(With projection:574D)
470W x 528D x 1003Hmm
(With projection:625D)
Weight 50kg 60kg 72kg
Rated voltage 230V AC
Power input 7A 9A 13A
Required power supply Single-phase 230V AC
(50/60 Hz)10 A or more
Single-phase 230V AC
(50/60 Hz)15 A or more
Single-phase 230V AC
(50/60 Hz)15 A or more
Power consumption (calorific value) 1.5kW(1290kcal/h) 2.0kW(1720kcal/h) 3.0kW(2580kcal/h)
Environmental Conditions When opereting the autoclave, observe the environmental conditions given below.
Ambient temperature: 10 to 35°C
Almospheric pressure: 860 to 1060hPa
Relative humidity: 30 to 85%
Maximum gradient: 2
Accessories Stainless baskets 1
(φ300×182 mm)
Stainless baskets 2
(φ300×182 mm)
Stainless baskets 2
(φ345×181 mm)
• Caster stopper 4, • Chamber bottom Plate 1, • Operator’s Manual 1, • Clear Plastic Accessory Case 1, • Attachment Screw for Clear Plastic Accessory Case 1, • Inspection Sheet 1, • Warranty card 1, • Customer card 1

*Please refer to the「 EC Declaration of Conformity」for detailed standard application.

* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.

MVE Lab Series Liquid Nitrogen Storage & Preservation

MVE Liquid Nitrogen Storage Solutions Lab Series from CSI Labshop Malaysia.

The Lab Series cryogenic liquid dewars are named for their acceptance in laboratories and medical facilities worldwide.

These high efficiency, super insulated dewars are the most convenient, economical way to store and dispense liquid nitrogen. Many lab units can be fitted with pouring spouts, pressurized dispensing devices or dippers to aid in the transfer of liquid nitrogen.

MVE Lab Series Liquid Nitrogen Storage Dewars and Tanks

MVE Lab Series

The Lab Series cryogenic liquid dewars are named for their acceptance in laboratories and medical facilities worldwide. These high efficiency, super insulated dewars are the most convenient, economical way to store and dispense liquid nitrogen. Many lab units can be fitted with pouring spouts, pressurized dispensing devices or dippers to aid in the transfer of liquid nitrogen.

Features Include:
• Designed for efficient storage of liquid nitrogen
• Low liquid nitrogen consumption
• Convenient lightweight package

 

For Liquid Nitrogen Storage Only – If you are storing samples (vials, canes, boxes, blood bags, etc.), please see SC Series, XC Series, or Cryosystem Series.

This unit comes with a cork and cover assembly. All other accessories not included.

 

MVE LN2 Lab Series Specifications

MVE LN2 Lab Series Diagram

MVE LN2 Lab Series Warranty

Lab Water Purification

Cascada

Lab Water Purification from PALL, USA.

CASCADA I SYSTEM

 

Output Water Quality

Water Type l

Resistivity (MΩ • cm @ 25ºC)  : 18.2
TOC(ppb)                                  : < 5 ***
Bacteria (cfu/mL)                        : <1*
Particles (>0.2 μm)                     : <1/mL*
Endotoxin (Eu/mL)                     : < 0.001 **
RNases (ng/mL)                          : < 0.01 **
DNases (pg/μL)                          : < 4 **

*    With 0.2 μm bacteria removal final filter0
**  With positive charged Nylon Ka1 endotoxin removal final filter
*** With feed TOC less than 2 ppm

Feed Water Requirements

Conductivity           : <100 μs/cm @ 25 ºC
Pressure                  : 0.1 ~ 6 bar
Temperature           : 5 ~ 35 ºC

Dimension (mm)

System                      : H 575 x W 366 x D 492
Reservoir                   : H1200/900/600 x W 390 x D 384
Pre-Treatment           : H 463 x W 220 x D 380
Dispensiong Station  : H 845 x W 280 x D 300

Net Weight (kg)

System                          : 23
Reservoir                      : 5(35L) ; 7(70L) ; 9 (105L)
Pre-Treatment              : 7
Dispensiong Station     : 6

Electrical Requirements

Input Voltage : 100-240 V 50-60 Hz
Power             : 200 VA Main Unit

Lab Equipment Calibration Service

Calibrate your lab equipment for precision and optimum performance.

CSI Labshop Malaysia provides calibration and maintenance service for your lab equipment We offer calibration solutions for equipments measuring dimensions, mass, temperature, pressuer, force, volumetric, electrical and many more. We work closely with competent calibrators to provide In-house calibration or externally validated calibration according to ISO or SAMM for testing measuring, control, and instrumentation. We can service onsite or offsite (pickup) instruments throughout Malaysia.  Fast service and low price guaranteed.  Ensure optimal performance and compliance in your laboratory equipment for precision and reliability.

Calibrate these instruments and equipment:

  • autoclave
  • fume hood
  • weighing scale or balance
  • hot plate
  • lab freezer
  • lab refrigerator
  • centrifuge
  • caliper, micrometers
  • incubator
  • ph meter
  • temperature meters
  • hygrometer
  • humidity meter
  • oven
  • drying oven
  • conductivity meter
  • many others

IKA Temperature Control Immersion and Water Bath

Temperature Control Solutions from IKA Thermostats Immersion and Water Baths

IKA thermostats ensure the safe and precise temperature control of liquids. The immersion thermostat tempers liquids up to 100 degrees centigrade. Able to withstand a heat output of 1,500 Watts, IKA thermostats are safe to use with all standard bath vessels. The circulation thermostat controls the temperature from 28 to 300 degrees centigrade and is fully geared towards safety and comfort. Highlights of the circulation thermostat include: Plug & Play technology, digital display, Easy Control, set point limiting, and a visual/acoustic alarm. Functionality, safety, and longevity are the main goals in the development of IKA thermostats.Find your ideal IKA thermostat by clicking on the adjacent categories
>> Full details of the product range are available here.
Compact Immersion Circulators ICC: The ICC is a compact immersion circulator for demanding and universal applications, based on an exceptionally well thought-out ergonomic concept and design.
Immersion Circulators IC: IC immersion circulators can be used to temper fluids to temperatures of up to 250°C. Thanks to the flexible bath bridge, the immersion circulator can be mounted on different sized baths.
Heated Bath Circulator HBC: HBC heated bath circulators heat up rapidly thanks to their high-quality insulation. The drain valve on the front allows the user to fully drain the bath safely.
Recirculating Chillers RC 2: The RC 2 is a high-efficiency circulating chiller with a powerful 400-W cooling system for temperature ranges of -20 to +40°C