WalkLAB Microprocessor pH meter TI9000

WalkLAB Microprocessor pH meter TI9000.

Ease of use
Automatically locks reading when a stable reading is established. This feature can be disabled to allow continuous reading display.

Automatic shut-off
Meter automatically shuts off after 5 minutes after the last key command. This feature can be disabled while reading in continuous read mode.

One-touch calibration
The meter’s one-touch auto-calibration procedure uses only one button to activate the mode. The unit will prompt and confirm offset and slope point calibration.

 

Microprocessor pH meter

Specifications

pH mV Temperature
Range: 0 to 14 pH ± 999 mV 0 to 100°C
Display Resolution: 0.01 pH 1 mV 0.1°C
Accuracy (machine only): ± 0.01 pH ± 1 mV ± 0.5°C
Temperature compensation: Automatic or manual from 0 to 100°C
Operating Temperature: 0 to 50°C
Operating humidity: Maximum 90% relative humidity
Slope recognition: ± 20% at pH 4 and pH 10
Offset recognition: ± 60 mV at pH 7
Input impedance 10¹² ohms
Battery type: DC9V (1604A, 6LF22 or equivalent)
Battery life: Approximately 200 hours
Size: 164 x 83 x 35mm
Weight: 350gm (main unit including battery)

 

Accessories 

1. Main instruments

2. PE03 – Epoxy body combination pH electrode

3. TP200 -pH microprocessor temperature probe (Stainless steel)

4. 7010 – Buffer solution pH7.00 90ml

5. 4010 – Buffer solution pH4.01 90ml

6. Carrying case

7. Operation manual

Interscience easySpiral® Dilute

Interscience easySpiral® Dilute

Easy spiral dilute

DISCOVER easySpiral® Dilute:

 

World’s first automatic serial diluter & plater: easySpiral® Dilute by INTERSCIENCE

INTERSCIENCE is proud to introduce easySpiral® Dilute, an automatic serial diluter and plater with full traceability. This innovative product enables you to make as many serial dilutions as you want and followed by automatic plating.

Automatic sample diluter & plater with full traceability
1. WORLD PREMIERE: ALL-IN-ONE DILUTER AND PLATER
- Save time: All-in-one dilution up to 10-5 and automatic plating (no more hours of dispensing tubes, autoclaving and washing tubes, no more pipette calibration)
- Save consumables: no more tips, reagents, Petri dishes
- User-friendly: one button touch for 10-5 serial dilution and plating
- Make as many dilutions as you want
- Increased accuracy : typical accuracy 0.5%

2. SO MUCH QUICKER !
- 5 automatic dilutions in 90 sec.
- 3 preset automatic plating modes
- Automatic standardized plating of 30 to 10 million CFU/mL on 1 Petri dish
- 25 seconds for a full cycle (disinfection, sample-taking and plating)
- 10 Petri dishes plated in less than 2 minutes (with the same sample)
- Revolutionary rotating arm with high-speed movement (Patented)

3. NO CROSS-CONTAMINATION
- Stylus disinfection system: inside and outside by overflow, 8 bars pressure (Patented)
- Unique patented system by overflow
- 600 cleanings without changing bottles

4. TRACEABILITY
- Increased repeatability within a team
- Easy PC connectivity via USB
- From 10 to 1000 microliters programmable volumes
- Monitoring software with traceability

5. EXCELLENT REPRODUCIBILITY AND REPEATABILITY
- In compliance with AFNOR V08-100 / ISO 7218

 

easySpiral® Dilute and FlexiPump®

Interscience easySpiral® Dilute and FlexiPump®

easySpiral® Dilute:  World’s first automatic diluter and plater!

• Does up to 5 serial 1/10 dilutions
• Standardized plating up to 1.1012 CFU/mL

 

FlexiPump®:  Peristaltic pumps for culture media preparation

• Dispenses liquid from 50 µL to 99 L !
• 32 editable programs & 3 dispensing modes

 

Barnstead Thermolyne® – 2200 Series Aluminum Top Hot Plates

 Barnstead Thermolyne®  –  2200 Series Aluminum Top Hot Plates

Large Surface for Large Loads!

Product Description

  • Aluminum top plate outperforms other materials; provides superior temperature uniformity and stability
  • Thermostatic temperature control provides excellent stability
  • Safe and reliable high temperature use
  • Cycle light indicates when power is being supplied to heating element
  • Stainless steel case provides optimal strength for heavy loads
  • Hot plate case is painted with epoxy paint for increased chemical resistance in corrosive environments
  • Large 12″ x 24″ (30.5 x 60.9 cm) top plate surface accommodates up to 40 lb (18.2 kg) loads
  • Recommended for use with glass vessels only

Application

  • Acid/Base digestions – trace metal analysis, etc.
  • Sample drying
  • General reagent heating
  • Heating TLC plates
  • Evaporations
Specifications:
Barnstead Thermolyne – HPA2240MQ
Min Temperature 38 °C / 100 °F
Max Temperature 371 °C / 700 °F
Heating Surface (Width x Depth) 12 x 24″ / 30.5 x 60.9 cm
Power 240 V / 13.30 A / 3200 W
Temperature Uniformity at 100°C ±10°C / ±18°F
Temperature Stability at 100°C ±3.5°C / ±6.3°F
Approvals CUL, UL
Comments HPA2240MQ Model not supplied with cord and plug due to high-wattage consumption requirements; must be connected through electrical conduit fittings
Overall Dimensions (Width x Height x Depth) 24 x 6.25 x 13.75″ / 60.9 x 15.9 x 34.9 cm
Shipping Weight 39 lb / 17.7 kg

 

PALMOIL TESTER

PALMOIL TESTER

A Fast Simple & Reliable Palm Oil Analysis System

PalmOilTester is a fast, simple and reliable testing system for crude or refined palm oil that enables the determination of acidity (FFA), DOBI & carotene content, the values of peroxide (PV), anisidine (AnV) and iodine (IV). With its simplicity, PalmOilTester is ideal to be used during every production stages in palm oil industry to monitor the quality of oil in real time, from the oil mill to the refinery plant, during the acceptance and storage phases, as well as during trading of finished products.

System Overview

PalmOilTester is constituted by:

  • A thermostated analyzer based on photometric technology that uses solid-state emitters.
  • A set of reagents prepared by CDR research laboratories.Reagents are supplied in bottles with a shelf life of one year. Furthermore, plastic cuvettes are supplied.
  • Pipettes with fixed calibration to ensure a correct collection of samples and an accurate dosing of reagents.
  • Print Manager: software that enables the analyzer to be connected to a PC in order to store and print the results of chemical tests.
  • User manual.
  • Illustrated data sheets.
  • DVD with filmed methods.

Features And Benefits

Fast

Test results are available in few minutes.

  • Acidity (FFA) in 1 minute
  • Peroxide Value (PV) in 4 minutes
  • DOBI & carotene content in 6 minutes
  • Iodine Value (IV) in 2 minutes
  • Anisidine Value (AnV) in 2 minutes

Simple

To run a test, it merely involves several simple

steps.

1. Add in exact amount of sample to the cuvette by using a pipette.

2. Homogenize it.

3. Initiate the test and result is available in few minutes.

4. Results are printed by a built-in printer.

At the end of test, there is no washing of containers, testing instrumentation or quartz cuvettes required. No additional equipment is necessary.

Minimizes Waste

As compared to official methods, it also minimizes waste, uses reagents with low toxicity and micro quantities of samples as it is.

Calibration Free

Unlike NIR and other photometric systems, it does not require complex calibration operations because it is supplied pre-calibrated. It is however possible to perform quick customized calibrations easily.

Reliable

PalmOilTester owes its high sensitivity, accuracy and reliability to: photometric technology that uses solid-state emitters, the digital signals processing, the possibility of aligning the system with reference standards and samples with known titration value, and the availability of reading and incubation cells thermostated at 37°C.

Correlated with AOCS/MPOB methods

Several comparative studies have demonstrated that the analytical accuracy of PalmOilTester matches that of referenced AOCS/MPOB methods, with the advantages that PalmOilTester is easier to use and outputs results much faster.

Well-documented

PalmOilTester comes with illustrated operational sheets and filmed test methods that help the user to be certain about the system practicability.


PalmOilTester Method

Acidity (FFA)

  • This testing method is simpler and faster as compared to the official method.
  • it guarantees high levels of accuracy and sensitivity, and is able to detect differences down to 0.01% of palmitic/lauric acid.
  • Unlike NIR systems, this method does not require calibration. Result are output in 1 minute.

Peroxide Value

  • This testing method is simpler and faster when compared to titration used in the official method.
  • The amount of reagent required is much smaller than the one used with the official method.
  • The reagents used have a low toxicity, unlike those employed in the official method that are highly toxic and polluting.
  • Results are output in 4 minutes.

Anisidine Value

  • This testing method is easier and faster as compared ti the official method. It takes only 3 minutes for each test.
  • It does not require dedicated instrumentation and technical staff.
  • It does not involve handling of highly toxic reagents.

Iodine Value

  • This is a valid screening test. It is easier and faster as compared to the official method.
  • It does not require glassware.
  • It involves small smount of low-toxic reagents when compared to official method requires a large amount of very toxic and polluting reagents.

DOBI & Carotene Content

  • This testing method is easier and faster as compared to the official method.
  • It does not require complex and expensive intrumentation.
  • It does not involve toxic reagents.
  • It does not require glassware,
  • It detects two important parameters, for crube palm oil quality, by doing a single test.

 

CR-14 COLOR READER

CR-14 COLOR READER

The CR-14 handheld color reader is a battery-operated, light-weight, whiteness index measuring inThe CR-14 handheld color reader is a battery-operated, light-weight, whiteness index measuring instrument.strument.

Image of CR-14 Konica Minolta Color Reader – An easy to use color measurement device

The CR-14 handheld color reader measures the whiteness of raw materials or foods in paste, solid, or powder form. The Hunter Whiteness Index or the CIE Whiteness Index—an international method for expressing whiteness—is displayed on the featured LCD screen. In the food industry, this is especially useful since color variations of white are especially obvious and can greatly influence consumer purchases.

The effect storage during transportation has on the whiteness of a product can be quantified by using this product. The CR-14 is lightweight, fits right in the palm of your hand, and is battery-operated, so it is very portable, or connect the unit to an AC adapter if that is preferred.

The device is easy-to-use, low cost, and ideal for industries that need inexpensive multiple devices or are just beginning to measure whiteness. Providing those functions necessary only for whiteness measuring makes it easy for anyone to use this instrument. There are only five steps: switch the power on, select the display mode, perform white calibration, place sample on the device, and press the button. Users then only need to look at the display to see measurement results.

Powders or pastes can be measured without needing to fill a cell with the CR-14′s protective cap, allowing for direct measurement of those substances. If users want to print results, simply connect the device to an external printer. A vinyl case to protect the instrument against dust is available as an option.

Illuminating/viewing geometry
8/d (8° illumination angle/diffuse viewing: specular component excluded)
Measuring area
Approx. Φ8mm
Display modes
Whiteness Index: CIE, Hunter, ASTM E313
Yellowness Index: ASTM E313, ASTM Dl925
Yxy (Displayable in CIE display mode)
Repeatability
Standard deviation of Whiteness Index: CIE: 0.5, Hunter: 0.1
(Measurement conditions: When measuring white calibration plate)
Minimum interval between measurements
Approx. 1 sec.
Power source
Four AA-size batteries or optional AC Adapter AC-A12
Battery life
Alkaline-manganese batteries: Approx.2000 measurements at10-sec. Intervals
Ni-Cd batteries: Approx. 600 measurements at 10-sec intervals
Operating temperature/humidity range
Temperature: 0 to 40°C;relative humidity 85% or less (at 35°C) with no condensation
Storage temperature/humidity range
-20 to 55°C; relative humidity 85% or less (at 35°C) with no condensation
Standard accessories
White Calibration Plate CR-A74, Soft Case CR-A68; Protective Cap CR-A79; Wrist Strap CR-A73; AA-size batteries (4)
Optional accessories