Axygen® MaxyGene™ II Thermal Cycler

The new MaxyGene II Thermal Cycler replaces our successful and reliable MaxyGene. It brings increased speed and advanced features, providing the premium performance you have come to expect from Axygen brand products.

Features

  • Unique flexible programming
  • Rapid run times
  • Improved workflow over traditional gradient cyclers
  • Ramping rates up to 5°C/sec.
  • Simple user interface
  • Adjustable heated lid accommodates strips, tubes and microplates
  • Pre-programmed standard protocols

Simplified Workflow – Improved Throughput
The MaxyGene II Thermal Cycler is extremely simple to program, compact in design and built to perform. The thermal cycler makes method optimization affordable and provides consistent, reliable results. It also features, Precision Thermal Control, rapid heating and cooling of the precision-machined sample block by six independently temperature controlled Peltier modules. A sophisticated algorithm program calculates sample temperature and triggers heating and cooling accordingly, minimizing over- and under-shooting. The MaxyGene II Thermal Cycler may be programmed to operate between one and six different annealing temperatures across the block. (See Figure 1) The thermal cycler provides improved throughput by reducing time and simplifies workflow by reducing steps.

A variety of applications – from single temperature soaks to sophisticated multistep programs can be performed with the MaxyGene II. All of these are easily set up. The time or temperature of a cycling step can be automatically increased or decreased during successive cycles. This is useful for “touchdown” applications and for extending annealing times as enzyme is depleted. Programs may also be paused while running. During operation, actual times and temperatures are displayed. Estimated run times are automatically calculated and a log of the last run can be displayed or downloaded to a printer or PC.

MaxyGene Thermal Cycler II Compatibility Guide
Well spacing in the MaxyGene Thermal Cycler II block is compatible with both thin walled thermal cycling plates and 0.2mL strip tubes. For best fit and performance, the use of Axygen thin walled polypropylene plates and tubes are recommended. Individual 0.2 mL tubes may also be used.

A & D Viscometer SV-A Series

Product Features

  • Requires a sample volume of only 2ml (SV-10A: 10ml or more) so users do not waste any samples and can save costs.
  • Titanium sensor plates
  • Fine position adjustment of the sample cup in three axial directions
Model SV-1A SV-10A SV-100A
Measurement Method Tuning Fork Vibration Method (Natural Frequency at 30Hz)
Viscosity Measurement Unit mPa·s,Pa·s,cP,P Pa·s,P
Viscosity Measurement Range 0.3~1000mPa·s 0.3~10000mPa·s 1~100Pa·s
Repeatability 1% of Reading (S.D., 20 – 30°C, No condensation)
Minimum Sample Amount 2ml~ 10ml~
Temperature Measurement 0~160°C / 0.1°C (32~320°F/0.1°F)
Display Vacuum Fluorescent Display (VFD)
Power Supply AC Adaptor (Approx. 14VA)
External Dimensions / Mass Main Unit: 112 (W)x132 (D)x291 (H) mm / Approx. 0.8kg
Display Unit: 138 (W)x132 (D)x170 (H) mm / Approx. 1.3kg
Standard Accessories Stand for Securing the Sensor Unit, X-Y-Z Stage, Cup Set
Software Set (including a Serial-USB Converter)
AC Adaptor, Connection Cable (1.5m), Carrying Case

A & D Viscometer SV-10/100 series

Product Features

  • High Measurement Accuracy
  • Wide Measurement Range
  • Non-Newtonian Sample Viscosity Measurement
  • Foam Sample Measurement
  • Flowing Sample Measurement
Models Vibration Frequency Measurement Range Unit of Measure
SV-10 30Hz 0.3 cP (mPa.s) ~
10,000 cP (mPa.s)
mPa.s, Pa.s, cP, P
SV-100 30Hz 10 P ~ 1,000 P Pa.s, P

WinCT Viscosity
Via an RS232C interface, the WinCT-Viscometer software lets A&D’s SV series Sine-wave Vibro Viscometer display measurement progress in real time on a PC, and easily transmit the measured results to save or analyze. The WinCT-Viscometer CD-ROM is a standard accessory with the SV Series viscometer.

RsVisco, the graphing software utilized by WinCT-Viscometer, lets you create graphs of measured results and of the progress of viscosity measurement:

1. RsVisco creates the real-time graph of data received from A&D’s SV-series viscometer via RS-232C. RxVisco lets you graphically monitor in real time:

  • Progress of change in viscosity during measurement
  • Temperature data
  • Temperature and viscosity, graphed together

2. You can choose from three types of graphs:

  • Viscosity (Y axis) – Time (X axis)
  • Viscosity/Temperature (Y axis) – Time (X axis)
  • Viscosity (Y axis) – Temperature (X axis)

3. Graphs can be overlaid in repeating measurements, in 10 colors.
4. Measured data can be saved in a CSV format file.
5. Displayed graphs can be printed with a printer via a PC

 

A & D Moisture Balance MS-70

Test with the Best – True 0.05% (standard deviation). The AND Weighing MS series moisture analyzers are ideal for food, pharmaceutical, chemical processing, or any moisture analysis application, particularly those needing GLP/GMP/ISO compliance. This one of a kind drying system, combined with an advanced heat protection mechanism for the weigh cell, provides superior accuracy and repeatability.

Special Features:

  • Fast & uniform heating with halogen lamp and uniquely designed SRA (Secondary Radiation Assist) filter
  • WinCT-Moisture Software (standard with MS & MX, option with MF) displays a real-time graph of moisture content rate change
  • Sodium Tartrate Dihydrate is provided as a stable moisture content for accuracy checks of the analyzer
  • Five Measurement Programs: Standard, Automatic, Timer, Manual, Quick
  • Clear and easy-to-see VFD display
  • Glass window for heating check and easy cleaning
  • Self-check function
  • Quick Reference Card
  • Standard bi-directional RS-232C
  • Conformity to GLP, GMP, GCP and ISO with time/date, ID, calibration data and check record outputs
  • High Repeatability of 0.01% with Super Hybrid Sensor Technology
  • Full Digital Calibration
  • Low Maintenance Cost

Specifications:

A&D – MS-70
Capacity 71 g
Readability 0.0001 g
Pan Size 85 mm dia. / 2.16″ dia.
Measurement Method 400W straight halogen lamp heating system with SRA filter and SHS weighing technology
Moisture Content Display 0.001% / 0.01% / 0.1%
Moisture Content Accuracy over 1g
(Standard Deviation)
0.05%
Moisture Content Accuracy over 5g
(Standard Deviation)
0.01%
Heating Technology Halogen lamp (Straight type, 400 Watt max, 5000 hours)
Drying Temperature (1°C increment) 30°C – 200°C / 86°F – 392°F
Memory of Measurement Programs 20 sets
Measurement Programs Standard Mode/Automatic Mode/Quick Mode/Timer Mode/Manual Mode
Measurement Mode Moisture content(Wet or Dry base) /Dry content/Ratio/Weight
Heating Mode Standard / Quick / Step / Ramp
Display Type Large VFD
Interface RS-232C standard
Data Memory Function 100
Operating Temperature 5°C – 40°C / 41°F – 104°F, less than 85%RH
GLP / GMP / ISO Available
Self Check Function Standard
Communication Software WinCT-Moisture standard
Power AC 100V to 120V (3A) or AC 200V to 240V (1.5A), 50/60 Hz, Approx. 400W
Scale Dimention (W x D x H) 215 x 320 x 173 mm / 8.46 x 12.60 x 6.81″
Weight Approx. 6 kg / 13.2 lbs

A & D Analytical Balance GR-300

The GR Series balances provide a larger weighing chamber and smaller footprint than conventional balances. These analytical balances are easy to use and calibrate, and adjust their settings based on environmental changes.

Special Features:

  • Requires 30% less footprint space
  • Fully Automatic Self-Calibration
  • One Touch Calibration
  • Easy Access Door
  • Splash Proof Keyboard and Display
  • Data Memory Function – Store up to 200 measurements
  • Two Layer Housing Construction
  • Advanced Stabilization Software
  • Automatic Adjustable Environment Setting
  • Multiple Weighing UnitsGLP Compliance
  • Standard RS-232C allows bidirectional communication with PC
  • Standard Underhook
  • Quick Reference Card
  • Bundled with A&D’s new WinCT Software
  • Built-in Motorized Calibration Weight

Specifications:

A&D – GR-300
Capacity 310g
Readability 0.1mg
Pan Size 85mm / 3.3″ dia.
Percentage Min Div 0.01%
Counting Min Weight 0.1 mg
Linearity ±0.0002 g
Repeatability / Std Dev 0.0001 g
Stabilization Time 3.5 Sec
Sensitivity Drift (10°C – 30°C) ±2ppm/°C (10°C ~ 30°C / 50°F ~ 86°F)
Display Refresh 5 times per second / 10 times per second
Physical Dimensions (W x D x H) 249 x 330 x 327mm / 9.8 x 12.99 x 12.87″
Breeze Break Dimensions (W x D x H) 178 x 160 x 233mm / 7.01 x 6.5 x 9.17″
Operating Temperature 5°C ~ 40°C / 41°F ~ 104°F, RH less than 85%
Weight Approximately 6.0 kg / 13.2 lb
Power 100, 120, 220, 240 VAC (AC Adapter) 50 Hz/60 Hz, 11VA
Standard Accessories Manual, AC Adapter, Reference Card
External Calibration Mass (optional) 200 g / 300 g