by williamsu | May 25, 2015 | Product News
Lamotte Combination Soil Testing Outfits Kit
This line of combination soil analysis outfits offers the finest visual color matching system available to today’s agronomist. Technically advanced reagent systems and unique extraction procedures based on the Mehlich I extraction provide fast, simple and extremely accurate soil testing.
The Model STH Combination Soil Outfits have offered simplified methods for determination of available nutrients found in agricultural soils for over forty years.
Since the original introduction of the STH series, based on Morgan soil test methods, reagent systems have been updated constantly with new advancements in modern chemistry. A series of rapid, accurate chemical tests use standardized reagents to produce color reactions measured against laminated color charts.
All STH outfits are furnished in lightweight carrying cases with components securely mounted in removable foam trays. This format provides flexibility for the in-house specialist who also wants to make quick problem determinations in the field.
Colorimetric test methods are used for most test factors. Tests for calcium, sulfate and chlorides are based on turbidity measurements. Potassium analysis also employs a turbidity measurement, using a unique reading device designed in LaMotte laboratories to read directly in pounds per acre. A single extraction procedure, using Morgan Universal Extraction Solution, provides the liquid soil extract for all the nutrient tests with the exception of chloride, which is extracted with demineralized water. The Humus Screening Test, performed on a soil sample-demineralized water suspension, employs five color standards for rapid measurement of humus content of the soil.
Soil pH is determined colorimetrically, using a series of pH indicators and color charts covering the range of pH 3.8 to 9.6. The STH outfits also include simplified procedures for screening nitrates, phosphorus, and potassium in plant tissues. Complete reagent refill packages are available for each STH outfit.
Each kit includes complete instructions, a soil management handbook and a pad of soil analysis report forms. The LaMotte Soil Handbook contains general information on interpretation of test results for determination of lime and fertilizer requirements.
Specifications
Model STH-4
Code 5029 |
Model STH-5
Code 5007 |
Model STH-7
Code 5061 |
Model STH-14
Code 5010-01 |
pH
pH 3.8-9.6
100 Tests |
pH
pH 3.8-9.6
100 Tests |
pH
pH 3.8-9.6
100 Tests |
pH
pH 3.8-9.6
100 Tests |
Nitrate Nitrogen
10-150 lbs/acre
50 Tests |
Nitrate Nitrogen
10-150 lbs/acre
50 Tests |
Nitrate Nitrogen
10-150 lbs/acre
50 Tests |
Nitrate Nitrogen
10-150 lbs/acre
50 Tests |
Phosphorus**
10-200 lbs/acre
50 Tests |
Phosphorus**
10-200 lbs/acre
50 Tests |
Phosphorus**
10-200 lbs/acre
50 Tests |
Phosphorus**
10-200 lbs/acre
50 Tests |
Potassium
100-400 lbs/acre
50 Tests |
Potassium
100-400 lbs/acre
50 Tests |
Potassium
100-400 lbs/acre
50 Tests |
Potassium
100-400 lbs/acre
50 Tests |
|
Humus (Organic Matter)
L-H 1.5%-8%
50 Tests |
Humus (Organic Matter)
L-H 1.5%-8%
50 Tests |
Humus (Organic Matter)
L-H 1.5%-8%
50 Tests |
|
|
Calcium
150-2800 ppm
50 Tests |
Calcium
150-2800 ppm
50 Tests |
|
|
Magnesium
L-H 5-150 ppm
50 Tests |
Magnesium
L-H 5-150 ppm
50 Tests |
|
|
|
Ammonia Nitrogen
L-H 5-150 ppm
50 Tests |
|
|
|
Manganese
L-H 4-40 ppm
50 Tests |
|
|
|
Aluminum
L-H 5-125 ppm
50 Tests |
|
|
|
Nitrite Nitrogen
1-50 ppm
50 Tests |
|
|
|
Sulfate
50-2000 ppm
50 Tests |
|
|
|
Chloride
25-500 ppm
50 Tests |
|
|
|
Ferric Iron
5-125 lbs/acre
50 Tests |
by williamsu | Apr 10, 2015 | Product News

Euromex Oxion series
The Oxion series has been specifically designed for the Exact- and Biomedical Sciences
Thanks to the high resolving power, a 3 Watt transmitted LED illumination, a 100 Watt Mercury fluorescence epi-illumination, multiple phase contrast, dark field set and the optional Apochromatic objectives, these microscopes can be used for all kind of demanding applications as well in fundamental research
- Wide Field eyepieces HWF 10x / 22
- Semi Plan SMP 4x, 10x, S40x and S100x-oil objectives for bright field contrast
- Plan PL 4x, 10x, 20x, S40x, S60x and S100x-oil objectives for bright field contrast
- Plan Phase PLPH 10x, 20x, S40x and S100x-oil objectivesfor phase contrast
- Plan Semi-Apochromatic PL APO 4x, 10x, 20x, S40x and S100x-oil objectives for bright field contrast
- Plan Semi-Apochromatic PL APO FLUAREX 4x, 10x, 20x, S40x and S100x-oil objectives for fluorescence
- Binocular withor without photo port
- Height adjustable Abbe condenser N.A. 1.25 with holder for phase sliders
- Zernike phase and bright field disc condenser with 4 phase rings
- Zernike phase and bright field disc condenser with 3 phase rings + dark field stop
- Cardioid dark field Oil-immersion condenser with built-in 5 W LED illumination
- Large stage with ball beared XY translation stage with optional heating elements and temperature controller
- Adjustable 3 Watt LED illumination
- 100 Watt mercury vapor lamp for fluorescence
- Many fluorphore filter sets available
Models OX.3012 and OX.3015 are equiped with standard Semi Plan objectives for bright field applications
Models OX.3020 to OX.3035 are equiped with standard Plan objectives for bright field applications
Models OX.3040 to OX.3047 are equiped with Plan Phase objectives for phase contrast
Models OX.3050 to OX.3065 are equiped with Plan Semi-Apochromatic objectivesfor bright field applications
Models OX.3070 to OX.3085 are equiped witht Plan Semi-Apochromatic objectives for fluorescence applications
Model OX.3064 is equipped with standard Plan objectives and a cardioid oil-immersion condenser with built-in 5 W LED illumination for dark field applications and living blood analysis
by williamsu | Mar 10, 2015 | Product News
TOMY AUTOCLAVES, SPEEDY SX-SERIES FROM JAPAN
Autoclaves SX series LineUP
Speedy Autoclaves
Maximized chamber capacity at Minimum installation space
Easy operation using the “Top-open lid”
A top-open lid, which can be operated easily with a single hand or foot, is provided with the SX autoclaves. To open the lid, the lid lock is released by stepping on the foot pedal locates at the bottom while pressing the lid down. The lid can be opened with minimal effort owing to mechanical assistance. In addition, the lid can be closed easily just by pressing it down.
Saving the installation space
The main body is very compact owing to the design which provides thorough installation space saving. In addition, installation space at the side of the main body which is required for models employing a slide-open lid, which is not necessary at SX autoclaves top-open lid. Even when several SX autoclaves are installed side-by-side, the necessary installation space is minimized.
A : 790mm(SX-300),970mm(SX-500),1003mm(SX-700)
B : 614mm(SX-300),794mm(SX-500),827mm(SX-700)
C : 410mm(SX-300/500),470mm(SX-700)
Easily viewable “work monitor”
The LED display shows working status for easy monitoring. The process being performed is indicated by an LED indication lamp blinking in red.
The illuminated display on the operating panel shown in the picture is different from the actual display at the time of operation.
Cooling fan provided as a standard feature
A rapid air-cooling function (vessel-cooling fan) permitting reduction of chamber cool down time is provided as a standard feature. This is most appropriate for lowering the temperature rapidly on completion of the cycle. The time required for lower the temperature is much reduced by employment of the cooling fan in comparison with natural cooling.
Sterilizing course selection
The optimal sterilizing course can be selected from among five courses, such as the liquid sterilizing course in addition to that for normal sterilization.

Other features
Large indication lamp “Operated”
An easily viewable large indication “Operated” is provided at the upper section of the operating panel.
Depending on the pressure status (normal pressure/pressure is applied),the displayed color changes.
Setting to 100°C is possible.
Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).
Auto-variable exhaust speed
A function allowing the exhaust valve to open automatically after completion of sterilization is provided. The exhaust speed can be set to one of six levels (set to variable for liquid sterilization)
Timer function
The operation starting time can be preset easily. By presetting the start of operation, otherwise wasted periods at night or early morning, can be used effectively.
Setting to 100°C is possible.
Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).
Lid interlock
A safety device (lid interlock mechanism) for locking the lid during operation is provided. A high level of safety is assured to prevent unanticipated accidents.
Pressure fine adjustment function
When the balance between the temperature and pressure deviates during sterilization, fine exhausting is carried out automatically in order to adjust the best chamber condition.
Functions & Features
Liquid sterilizing / Heating / Warming / Check / Last-run memory / Built-in steam exhaust bottle
Flat internal surface of the chamber / Lid opening/closing detection mechanism
Exhaust bottle detection mechanism / Leakage breaker provided
OPTION
External sensor for the articles to be sterilized
Sensor for directly detecting the temperature of articles to be sterilized. More reliable sterilization monitor can be carried out.
Data output
The temperature data, pressure data, etc. can be exported. The temperature can be recorded when the external recorder is connected.
External sensor and recorder
A temperature sensor and recorder independent of the autoclaves. The chamber temperature can be recorded.
SX Specifications
| Model name |
SX-300 |
SX-500 |
SX-700 |
| Operating temperature range |
Sterilizing |
105 ∼ 135°C(0.019 ∼ 0.212MPa) |
| Heating |
45 ∼ 104°C(0 ∼ 0.015MPa) |
| Warming |
45 ∼ 95°C |
| Maximum operating pressure |
0.263MPa |
0.25MPa |
| Temperature |
Display |
Digital |
| Pressure gauge |
Display |
Analog |
| Display range |
0 ∼ 0.4MPa |
| Heat source |
1.5kW electric heater |
2kW electric heater |
3kW electric heater |
| Safety device |
• Water level sensor, • Current leakage breaker, • Lid interlock, • Over-heat prevention, • Over-pressure prevention, • Open temperature sensor detection, • Safety valve |
| Time |
Display |
Digital |
Display
range |
Sterilizing |
0:00 – 9:59, 0 – 99hours, 0 – 999min.(0:00 – 9:59,10 – 99hours changeable) |
| Heating |
| Warming |
Variable: 0 – 99hours |
| Chamber dimensions |
φ325 x 553mm |
φ325 x 733mm |
φ370 x 774mm |
| Chamber capacity |
Effective internal
volume:36L,
Internal volume:44L |
Effective internal
volume:50L,
Internal volume:58L |
Effective internal
volume:69L,
Internal volume:79L |
| Chamber material |
SUS304 |
| Dimensions (mm) |
410W x 477D x 790Hmm
(With protruding:574D) |
410W x 477D x 970Hmm
(With protruding:574D) |
470W x 528D x 1003Hmm
(With protruding:625D) |
| Weight |
50kg |
60kg |
72kg |
| Rated voltage |
120V AC |
– |
| 230V AC |
| Power input |
13A/120V |
17A/120V |
– |
| 7A/230V |
9A/230V |
13A/230V |
| Required power supply |
Single-phase 120V AC
(50/60 Hz)15A or more |
Single-phase 120V AC
(50/60 Hz)20A or more |
– |
Single-phase 230V AC
(50/60 Hz)10A or more |
Single-phase 230V AC
(50/60 Hz)15A or more |
Single-phase 230V AC
(50/60 Hz)15 A or more |
| Power consumption (calorific value) |
1.5kW (1290kcal/h) |
2.0kW (1720cal/h) |
3.0kW (2580cal/h) |
| Environmental Conditions |
When opereting the autoclave, observe the environmental conditions given below.
Ambient temperature: 10 to 35°C
Almospheric pressure: 860 to 1060hPa
Relative humidity: 30 to 85%
Maximum gradient: 2 |
| Accessories |
Stainless baskets 1
(φ300 x 182mm) |
Stainless baskets 2
(φ300 x 182mm) |
Stainless baskets 2
(φ345 x 181mm) |
| • Chanber bottom Plate 1, • Caster stoppers 4, • Operator’s Manual 1, • Clear folder (for storing the operation manual) 1, • Screw (for attaching the clear folder) 1, • Warranty card 1, • Customer card 1, • Inspection Sheet 1 |
SX-E Specifications
| Model name |
SX-300E |
SX-500E |
SX-700E |
| Operating temperature range |
Sterilizing |
105 ∼ 135°C (0.019 ∼ 0.212MPa) |
| Heating |
45 ∼ 104°C (0 ∼ 0.015MPa) |
| Warming |
45 ∼ 95°C |
| Maximum operating pressure |
0.263MPa |
0.25MPa |
| Temperature |
Display |
Digital |
| Pressure gauge |
Display |
Analog |
| Display range |
0 – 0.4MPa |
| Heat source |
1.5kW electric heater |
2.0kW electric heater |
3.0kW electric heater |
| Safety device |
• Water level sensor, • Leakage breaker, • Lid interlock, • Over-heat prevention, • Over-pressure prevention, • Temperature sensor break detection, • Safety valve |
| Protection type against electrical shock |
Class I equipment |
| Time |
Display |
Digital |
Display
range |
Sterilizing |
0:00 – 9:59, 0 – 99hours, 0 – 999min.(0:00 – 9:59,10 – 99hours changeable) |
| Heating |
| Warming |
Variable: 0 – 99hours |
| Pressure chamber type |
PED Category II |
| Chamber dimensions |
φ325 x 553mm |
φ325 x 733mm |
φ370 x 774mm |
| Chamber capacity |
Effective internal
volume:36L,
Internal volume:44L |
Effective internal
volume:50L,
Internal volume:58L |
Effective internal
volume:69L,
Internal volume:79L |
| Chamber material |
SUS304 |
| Dimensions (mm) |
410W x 477D x 790Hmm
(With projection:574D) |
410W x 477D x 970Hmm
(With projection:574D) |
470W x 528D x 1003Hmm
(With projection:625D) |
| Weight |
50kg |
60kg |
72kg |
| Rated voltage |
230V AC |
| Power input |
7A |
9A |
13A |
| Required power supply |
Single-phase 230V AC
(50/60 Hz)10 A or more |
Single-phase 230V AC
(50/60 Hz)15 A or more |
Single-phase 230V AC
(50/60 Hz)15 A or more |
| Power consumption (calorific value) |
1.5kW(1290kcal/h) |
2.0kW(1720kcal/h) |
3.0kW(2580kcal/h) |
| Environmental Conditions |
When opereting the autoclave, observe the environmental conditions given below.
Ambient temperature: 10 to 35°C
Almospheric pressure: 860 to 1060hPa
Relative humidity: 30 to 85%
Maximum gradient: 2 |
| Accessories |
Stainless baskets 1
(φ300×182 mm) |
Stainless baskets 2
(φ300×182 mm) |
Stainless baskets 2
(φ345×181 mm) |
| • Caster stopper 4, • Chamber bottom Plate 1, • Operator’s Manual 1, • Clear Plastic Accessory Case 1, • Attachment Screw for Clear Plastic Accessory Case 1, • Inspection Sheet 1, • Warranty card 1, • Customer card 1 |
*Please refer to the「 EC Declaration of Conformity」for detailed standard application.
* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.
by williamsu | Mar 10, 2015 | Product News
MVE Liquid Nitrogen Storage Solutions Lab Series from CSI Labshop Malaysia.
The Lab Series cryogenic liquid dewars are named for their acceptance in laboratories and medical facilities worldwide.
These high efficiency, super insulated dewars are the most convenient, economical way to store and dispense liquid nitrogen. Many lab units can be fitted with pouring spouts, pressurized dispensing devices or dippers to aid in the transfer of liquid nitrogen.
MVE Lab Series Liquid Nitrogen Storage Dewars and Tanks
MVE Lab Series
The Lab Series cryogenic liquid dewars are named for their acceptance in laboratories and medical facilities worldwide. These high efficiency, super insulated dewars are the most convenient, economical way to store and dispense liquid nitrogen. Many lab units can be fitted with pouring spouts, pressurized dispensing devices or dippers to aid in the transfer of liquid nitrogen.
Features Include:
• Designed for efficient storage of liquid nitrogen
• Low liquid nitrogen consumption
• Convenient lightweight package
For Liquid Nitrogen Storage Only – If you are storing samples (vials, canes, boxes, blood bags, etc.), please see SC Series, XC Series, or Cryosystem Series.
This unit comes with a cork and cover assembly. All other accessories not included.



by williamsu | Mar 4, 2015 | Product News

Lab Water Purification from PALL, USA.
CASCADA I SYSTEM
Output Water Quality
Water Type l
Resistivity (MΩ • cm @ 25ºC) : 18.2
TOC(ppb) : < 5 ***
Bacteria (cfu/mL) : <1*
Particles (>0.2 μm) : <1/mL*
Endotoxin (Eu/mL) : < 0.001 **
RNases (ng/mL) : < 0.01 **
DNases (pg/μL) : < 4 **
* With 0.2 μm bacteria removal final filter0
** With positive charged Nylon Ka1 endotoxin removal final filter
*** With feed TOC less than 2 ppm
Feed Water Requirements
Conductivity : <100 μs/cm @ 25 ºC
Pressure : 0.1 ~ 6 bar
Temperature : 5 ~ 35 ºC
Dimension (mm)
System : H 575 x W 366 x D 492
Reservoir : H1200/900/600 x W 390 x D 384
Pre-Treatment : H 463 x W 220 x D 380
Dispensiong Station : H 845 x W 280 x D 300
Net Weight (kg)
System : 23
Reservoir : 5(35L) ; 7(70L) ; 9 (105L)
Pre-Treatment : 7
Dispensiong Station : 6
Electrical Requirements
Input Voltage : 100-240 V 50-60 Hz
Power : 200 VA Main Unit