Calibrate your lab equipment for precision and optimum performance.

CSI Labshop Malaysia provides calibration and maintenance service for your lab equipment We offer calibration solutions for equipments measuring dimensions, mass, temperature, pressuer, force, volumetric, electrical and many more. We work closely with competent calibrators to provide In-house calibration or externally validated calibration according to ISO or SAMM for testing measuring, control, and instrumentation. We can service onsite or offsite (pickup) instruments throughout Malaysia. Fast service and low price guaranteed. Ensure optimal performance and compliance in your laboratory equipment for precision and reliability.
Calibrate these instruments and equipment:
- autoclave
- fume hood
- weighing scale or balance
- hot plate
- lab freezer
- lab refrigerator
- centrifuge
- caliper, micrometers
- incubator
- ph meter
- temperature meters
- hygrometer
- humidity meter
- oven
- drying oven
- conductivity meter
- many others
by williamsu | Feb 28, 2015 | Product News

Temperature Control Solutions from IKA Thermostats Immersion and Water Baths
|
|
IKA thermostats ensure the safe and precise temperature control of liquids. The immersion thermostat tempers liquids up to 100 degrees centigrade. Able to withstand a heat output of 1,500 Watts, IKA thermostats are safe to use with all standard bath vessels. The circulation thermostat controls the temperature from 28 to 300 degrees centigrade and is fully geared towards safety and comfort. Highlights of the circulation thermostat include: Plug & Play technology, digital display, Easy Control, set point limiting, and a visual/acoustic alarm. Functionality, safety, and longevity are the main goals in the development of IKA thermostats.Find your ideal IKA thermostat by clicking on the adjacent categories
>> Full details of the product range are available here. |
 |
ICC: The ICC is a compact immersion circulator for demanding and universal applications, based on an exceptionally well thought-out ergonomic concept and design. |
 |
IC: IC immersion circulators can be used to temper fluids to temperatures of up to 250°C. Thanks to the flexible bath bridge, the immersion circulator can be mounted on different sized baths. |
 |
HBC: HBC heated bath circulators heat up rapidly thanks to their high-quality insulation. The drain valve on the front allows the user to fully drain the bath safely. |
 |
RC 2: The RC 2 is a high-efficiency circulating chiller with a powerful 400-W cooling system for temperature ranges of -20 to +40°C |
|
by williamsu | Feb 27, 2015 | Product News
Tomy Autoclaves (JKKP approved models) is now available from CSI Labshop Malaysia
Autoclaves SX series LineUP
Speedy Autoclaves
Maximized chamber capacity at Minimum installation space
Easy operation using the “Top-open lid”
A top-open lid, which can be operated easily with a single hand or foot, is provided with the SX autoclaves. To open the lid, the lid lock is released by stepping on the foot pedal locates at the bottom while pressing the lid down. The lid can be opened with minimal effort owing to mechanical assistance. In addition, the lid can be closed easily just by pressing it down.
Saving the installation space
The main body is very compact owing to the design which provides thorough installation space saving. In addition, installation space at the side of the main body which is required for models employing a slide-open lid, which is not necessary at SX autoclaves top-open lid. Even when several SX autoclaves are installed side-by-side, the necessary installation space is minimized.
A : 790mm(SX-300),970mm(SX-500),1003mm(SX-700)
B : 614mm(SX-300),794mm(SX-500),827mm(SX-700)
C : 410mm(SX-300/500),470mm(SX-700)
Easily viewable “work monitor”
The LED display shows working status for easy monitoring. The process being performed is indicated by an LED indication lamp blinking in red.
The illuminated display on the operating panel shown in the picture is different from the actual display at the time of operation.
Cooling fan provided as a standard feature
A rapid air-cooling function (vessel-cooling fan) permitting reduction of chamber cool down time is provided as a standard feature. This is most appropriate for lowering the temperature rapidly on completion of the cycle. The time required for lower the temperature is much reduced by employment of the cooling fan in comparison with natural cooling.
Sterilizing course selection
The optimal sterilizing course can be selected from among five courses, such as the liquid sterilizing course in addition to that for normal sterilization.

Other features
Large indication lamp “Operated”
An easily viewable large indication “Operated” is provided at the upper section of the operating panel.
Depending on the pressure status (normal pressure/pressure is applied),the displayed color changes.
Setting to 100°C is possible.
Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).
Auto-variable exhaust speed
A function allowing the exhaust valve to open automatically after completion of sterilization is provided. The exhaust speed can be set to one of six levels (set to variable for liquid sterilization)
Timer function
The operation starting time can be preset easily. By presetting the start of operation, otherwise wasted periods at night or early morning, can be used effectively.
Setting to 100°C is possible.
Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).
Lid interlock
A safety device (lid interlock mechanism) for locking the lid during operation is provided. A high level of safety is assured to prevent unanticipated accidents.
Pressure fine adjustment function
When the balance between the temperature and pressure deviates during sterilization, fine exhausting is carried out automatically in order to adjust the best chamber condition.
Functions & Features
Liquid sterilizing / Heating / Warming / Check / Last-run memory / Built-in steam exhaust bottle
Flat internal surface of the chamber / Lid opening/closing detection mechanism
Exhaust bottle detection mechanism / Leakage breaker provided
OPTION
External sensor for the articles to be sterilized
Sensor for directly detecting the temperature of articles to be sterilized. More reliable sterilization monitor can be carried out.
Data output
The temperature data, pressure data, etc. can be exported. The temperature can be recorded when the external recorder is connected.
External sensor and recorder
A temperature sensor and recorder independent of the autoclaves. The chamber temperature can be recorded.
SX Specifications
| Model name |
SX-300 |
SX-500 |
SX-700 |
| Operating temperature range |
Sterilizing |
105 ∼ 135°C(0.019 ∼ 0.212MPa) |
| Heating |
45 ∼ 104°C(0 ∼ 0.015MPa) |
| Warming |
45 ∼ 95°C |
| Maximum operating pressure |
0.263MPa |
0.25MPa |
| Temperature |
Display |
Digital |
| Pressure gauge |
Display |
Analog |
| Display range |
0 ∼ 0.4MPa |
| Heat source |
1.5kW electric heater |
2kW electric heater |
3kW electric heater |
| Safety device |
• Water level sensor, • Current leakage breaker, • Lid interlock, • Over-heat prevention, • Over-pressure prevention, • Open temperature sensor detection, • Safety valve |
| Time |
Display |
Digital |
Display
range |
Sterilizing |
0:00 – 9:59, 0 – 99hours, 0 – 999min.(0:00 – 9:59,10 – 99hours changeable) |
| Heating |
| Warming |
Variable: 0 – 99hours |
| Chamber dimensions |
φ325 x 553mm |
φ325 x 733mm |
φ370 x 774mm |
| Chamber capacity |
Effective internal
volume:36L,
Internal volume:44L |
Effective internal
volume:50L,
Internal volume:58L |
Effective internal
volume:69L,
Internal volume:79L |
| Chamber material |
SUS304 |
| Dimensions (mm) |
410W x 477D x 790Hmm
(With protruding:574D) |
410W x 477D x 970Hmm
(With protruding:574D) |
470W x 528D x 1003Hmm
(With protruding:625D) |
| Weight |
50kg |
60kg |
72kg |
| Rated voltage |
120V AC |
– |
| 230V AC |
| Power input |
13A/120V |
17A/120V |
– |
| 7A/230V |
9A/230V |
13A/230V |
| Required power supply |
Single-phase 120V AC
(50/60 Hz)15A or more |
Single-phase 120V AC
(50/60 Hz)20A or more |
– |
Single-phase 230V AC
(50/60 Hz)10A or more |
Single-phase 230V AC
(50/60 Hz)15A or more |
Single-phase 230V AC
(50/60 Hz)15 A or more |
| Power consumption (calorific value) |
1.5kW (1290kcal/h) |
2.0kW (1720cal/h) |
3.0kW (2580cal/h) |
| Environmental Conditions |
When opereting the autoclave, observe the environmental conditions given below.
Ambient temperature: 10 to 35°C
Almospheric pressure: 860 to 1060hPa
Relative humidity: 30 to 85%
Maximum gradient: 2 |
| Accessories |
Stainless baskets 1
(φ300 x 182mm) |
Stainless baskets 2
(φ300 x 182mm) |
Stainless baskets 2
(φ345 x 181mm) |
| • Chanber bottom Plate 1, • Caster stoppers 4, • Operator’s Manual 1, • Clear folder (for storing the operation manual) 1, • Screw (for attaching the clear folder) 1, • Warranty card 1, • Customer card 1, • Inspection Sheet 1 |
SX-E Specifications
| Model name |
SX-300E |
SX-500E |
SX-700E |
| Operating temperature range |
Sterilizing |
105 ∼ 135°C (0.019 ∼ 0.212MPa) |
| Heating |
45 ∼ 104°C (0 ∼ 0.015MPa) |
| Warming |
45 ∼ 95°C |
| Maximum operating pressure |
0.263MPa |
0.25MPa |
| Temperature |
Display |
Digital |
| Pressure gauge |
Display |
Analog |
| Display range |
0 – 0.4MPa |
| Heat source |
1.5kW electric heater |
2.0kW electric heater |
3.0kW electric heater |
| Safety device |
• Water level sensor, • Leakage breaker, • Lid interlock, • Over-heat prevention, • Over-pressure prevention, • Temperature sensor break detection, • Safety valve |
| Protection type against electrical shock |
Class I equipment |
| Time |
Display |
Digital |
Display
range |
Sterilizing |
0:00 – 9:59, 0 – 99hours, 0 – 999min.(0:00 – 9:59,10 – 99hours changeable) |
| Heating |
| Warming |
Variable: 0 – 99hours |
| Pressure chamber type |
PED Category II |
| Chamber dimensions |
φ325 x 553mm |
φ325 x 733mm |
φ370 x 774mm |
| Chamber capacity |
Effective internal
volume:36L,
Internal volume:44L |
Effective internal
volume:50L,
Internal volume:58L |
Effective internal
volume:69L,
Internal volume:79L |
| Chamber material |
SUS304 |
| Dimensions (mm) |
410W x 477D x 790Hmm
(With projection:574D) |
410W x 477D x 970Hmm
(With projection:574D) |
470W x 528D x 1003Hmm
(With projection:625D) |
| Weight |
50kg |
60kg |
72kg |
| Rated voltage |
230V AC |
| Power input |
7A |
9A |
13A |
| Required power supply |
Single-phase 230V AC
(50/60 Hz)10 A or more |
Single-phase 230V AC
(50/60 Hz)15 A or more |
Single-phase 230V AC
(50/60 Hz)15 A or more |
| Power consumption (calorific value) |
1.5kW(1290kcal/h) |
2.0kW(1720kcal/h) |
3.0kW(2580kcal/h) |
| Environmental Conditions |
When opereting the autoclave, observe the environmental conditions given below.
Ambient temperature: 10 to 35°C
Almospheric pressure: 860 to 1060hPa
Relative humidity: 30 to 85%
Maximum gradient: 2 |
| Accessories |
Stainless baskets 1
(φ300×182 mm) |
Stainless baskets 2
(φ300×182 mm) |
Stainless baskets 2
(φ345×181 mm) |
| • Caster stopper 4, • Chamber bottom Plate 1, • Operator’s Manual 1, • Clear Plastic Accessory Case 1, • Attachment Screw for Clear Plastic Accessory Case 1, • Inspection Sheet 1, • Warranty card 1, • Customer card 1 |
*Please refer to the「 EC Declaration of Conformity」for detailed standard application.
* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.
by williamsu | Feb 24, 2015 | Product News