TGA/DSC 1 – Thermogravimetric Analyzer

The heart of a TGA is the balance cell. Our TGA instruments use the world’s best micro and ultra-micro balances. By using one of the three removable sensor types the TGA/DSC 1 simultaneously measures heat flow in addition to weight change. Thanks to its modular design, the TGA/DSC 1 is the ideal instrument for manual or automated operation in production and quality assurance through to research and development.

  • High resolution – ultra-microgram resolution over the whole measurement range
  • DSC heat flow measurement – for simultaneous detection of thermal events
  • Modular concept – tailor-made solutions for current and future needs

Innovative Technology

Features and Benefits of the TGA/DSC 1 – Thermogravimetric Analyzer

METTLER TOLEDO ultra-micro balance – rely on the balance technology leader
Efficient automation – most reliable sample robot for high sample throughput
Wide measurement range – measure small and large sample masses and volumes
Broad temperature scale – analyze samples from ambient to 1600 °C
DSC heat flow measurement – for simultaneous detection of thermal events
Hyphenated techniques – evolved gas analysis using MS and FTIR
Modular concept – tailor-made solutions for current and future needs

Specifications – TGA/DSC 1 – Thermogravimetric Analyzer

Temperature range RT … 1100 °C or 1600 °C
Heating rate (LF/SF) 0.02…150/250 K/min
Cooling: 1100 … 60 °C 8.8 min
Balance resolution 0.1/1 µg (depending on balance model)
Material Number(s) 51142003

 

TGA 1 – Thermogravimetric Analyzer

The heart of a TGA is the balance cell. Our TGA instruments use the world’s best micro and ultra-micro balances. Thanks to its modular design, the TGA 1 is the ideal instrument for manual or automated operation in production and quality assurance through to research and development.

  • High resolution – ultra-microgram resolution over the whole measurement range
  • Wide measurement range – measure small and large sample masses and volumes
  • Modular concept – tailor-made solutions for current and future needs

Innovative Technology

Features and Benefits of the TGA 1 – Thermogravimetric Analyzer

METTLER TOLEDO ultra-micro balance – rely on the balance technology leader
Efficient automation – most reliable sample robot for high sample throughput
Wide measurement range – measure small and large sample masses and volumes
Broad temperature scale – analyze samples from ambient to 1100 °C
Hyphenated techniques – evolved gas analysis using MS and FTIR
Modular concept – tailor-made solutions for current and future needs

Specifications – TGA 1 – Thermogravimetric Analyzer

Temperature range RT … 1100 °C
Heating rate 0.02…150/250 K/min
Cooling: 1100 … 60 °C 8.8 min
Balance resolution 0.1/1 µg (depending on balance model)
Material Number(s) 30064763

HP DSC 1 – High Pressure Differential Scanning Calorimeter

Increased pressure influences all physical changes and chemical reactions in which a change in volume occurs. For material testing, process development or quality control there is often no alternative to DSC measurements under pressure.

  • Shorter analysis time – higher pressure and temperature accelerate reactions
  • Measurements under process conditions – simulation of practical reaction environments
  • Better interpretation – effects can be separated by suppressing vaporization

Innovative Technology

Features and Benefits of the HP DSC 1

Shorter analysis time – higher pressure and temperature accelerate reactions
Measurements under process conditions – simulation of practical reaction environments
Better interpretation – effects can be separated by suppressing vaporization
Suppresses and delays vaporization – separation of a reaction from overlapping vaporization
Higher gas concentrations – reaction rate of heterogeneous reactions with gases is increased
Measurements under special atmospheres – oxidative, oxygen-free conditions or measurements with toxic or combustible gases are possible
Possibility of working at different pressures – more accurate measurement of adsorption and desorption behavior

Specifications – HP DSC 1 – High Pressure Differential Scanning Calorimeter

Temperature range RT … 500 °C / 700 °C
Heating rate 0.1…50 K/min
Pressure range 0 … 10 MPa (overpressure)
Gas flow Freely selectable; accurate control of purge gas flow and total pressure with external controller
Atmospheres Measurements under different atmospheres: inert, oxidizing, reducing, reactive, e.g. nitrogen, oxygen, hydrogen, methyl bromide, ethylene, propylene, carbon dioxide, etc. There are certain restrictions for combustible and toxic gases
Material Number(s) 51143145
Trade Name DSC

DSC 1 – Differential Scanning Calorimeter

Thanks to its modular design, the DSC 1 as part of the METTLER TOLEDO Thermal Analysis Excellence Line is the best choice for manual or automatic operation, from quality assurance and production through to research and development. The DSC utilizes an innovative patented DSC sensor with 120 thermocouples which guarantees unmatched sensitivity.

  • High sensitivity – for weak transitions
  • Outstanding resolution – separation of closely lying effects
  • Modular design – allows future expansion to meet new need

Features and Benefits of the DSC 1

Innovative Technology

Amazing sensitivity – for the measurement of weak effects
Outstanding resolution – allows measurement of rapid changes and close-lying effects
Efficient automation – most reliable 34-sample position sample robot for high sample throughput
Small and large sample volumes – for microgram or inhomogeneous samples
Modular concept – tailor-made solutions for current and future needs
Flexible calibration and adjustment – guarantees accurate and precise measurement results under all conditions
Wide temperature range – from –150 °C to 700 °C in one measurement
Ergonomic design – intelligence, simplicity and safety facilitate your daily work

Specifications – DSC 1 – Differential Scanning Calorimeter

Temperature range -150 …700 °C depending on cooling and furnace option
Sensor FRS 5 with 56 thermocouples or HSS8 with 120 thermocouples
Sampling rate max. 50 Hz
User Interface 320×240 pixel Touchscreen control and Touch-free SmartSens
Connection to computer Ethernet
Material Number(s) 51142003
Trade Name DSC

SANPLATEC ACRYLIC VACUUM GLOVEBOX VSC-800

SANPLATEC ACRYLIC VACUUM GLOVEBOX VSC-800

Features

First commercialization in Japan of this type of all acryl.

Insertion and removal of work devices is performed at left side door. In addition, insertion and removal of material samples during work is performed through a right pass box. Strength is designed to withstand even a complete vacuum.

The VG-800 is equipped with a 100V tap as standard. Use it when using a power supply at the inside.

* There is a record of delivery of chamber 3 coupling and work use vacuum chamber. Designed and manufactured to meet your site needs.

(Option examples)
Installation of electrode terminal 2 pins, 4 pins, and 16 pins, Gas introduction opening (inside, outside), Modifi cation of valve outside diameter.

Code Model
6590 VSC-800  

Specification

Outside Dimentions 1209W x 648D x 660H mm
Effective inner dimentions 709W x 155D (Top) /370D (Bottom) x 450H mm
Pass box inside dimensions 310W x 200D x 200H mm
Valve Chamber 2
Pass box 2
Glove port 1
Pump connection side 2
Vacuum gauges Main chamber, Pass box 1 each (for 0 to -0.1MPa)
Glove, glove with band 1 set
Glove port door 1 set (used at decompression)
Receptacle 3P-2 serial taps
Weight Approx. 94kg

* Nozzle of hose nipple type valve is 9mm.

Note : Both the body and pass box of this vacuum glove box are so designed to withstand a complete vacuum, but since sudden suction and inhalation causes damage and deterioration of life to speed up, perform them as slowly as possible.
When using as a vacuum desiccator, always use with the glove cap installed.
The vacuum gauge shows the atmospheric pressure and glove box interior pressure difference. (Units: MPa)