Orion 2117XP Chloride Analyzer
Thermo Scientific Orion 2117XP Chloride Analyzer detects chloride in real-time, providing accurate and reliable results.
Early detection of chloride ingress from feedwater helps your plant maintain the optimal balance of water purification with ease and peace of mind.

- Detection limit of 0.1ppm – offers continuous chloride monitoring in wide variety of samples
- Protect against early breakthrough with sensitive, selective, reliable and verfiable measurements that provide early detection of chloride in RO and boiler systems
- Holds calibration up to 60 days between reagent changes
- Fast and highly accurate calibration has you back online in minutes
- Long life solid state sensor technology offers stability and high performance
- Simple operation and minimal maintenance required – no moving parts
- Repeatable and verifiable measurements at a glance using the large, user friendly display
Ordering Alerts: 2117XP Chloride Analyzer Ordering Information
- Annual Consumables Kit, Cat. No. 211750XP
- Reagent, Cat. No. 182011
- Diffusion Tubing, Cat. No. 181060
- Calibration Kit, Cat. No. 2117XPCAL
- Calibration Standards, Cat. No. 211740
- Chloride Electrode, Cat. No. 100025
- Reference Electrode, Cat. No. 100057
- Reference Electrode Filling Solution, Cat. No. 100057F4
Specifications | |
---|---|
Response Time | Reach 95% of final reading within 2 minutes of injecting a standard solution |
Units Displayed | ppb, ppm (auto ranging) |
Temperature | 5° to 35°C |
Total Alkalinity | <50ppm CaCO3 |
Inlet Pressure | 8 to 100psig |
Flowrate | 40mL/min. nominal set by pressure regulator |
Sample Inlet | 1/4 in. NPTF tube fitting |
Sample Drain | 3/4 in. NPT male |
Display | Custom backlit LCD with temperature, concentration, mV, error codes, menu driven prompts |
ATC | 2 x NTC 30 K |
Specific Ion Input and Reference | Potentiometric |
Analog Output | Galvanically isolated |
Number of Analog Outputs | 2, one dedicated to chloride, one to temperature; shared ground |
Output Selections | 0 to 20mA or 4 to 20mA |
Programmable Range | YES |
Log and Linear Output Options : | Yes, user selectable |
Alarm Outputs | 3 |
Number of Relay Outputs | 3 |
Maximum Relay Load | 250VAC 30VDC 5A |
Min./Max. Value Alarm | YES |
Error Alarm | YES |
Calibration/Offline Alarm | YES |
Programmable min. and max. values | YES |
Electronics | 5.66 x 5.66 x 7.36 in. (144 x 144 x 187mm) |
Entire System Dimensions | 26 x 17 x 11 in. (65 x 45 x 27cm) Fits on 1817AO panel mounting footprint. |
Input | 85 to 132 or 170 to 264VAC |
Self-test Diagnostics | YES |
Password Protection | YES |
Programmable Alarms | High, low, error, calibration/offline |
Waterproof Enclosure | IP66 and NEMA 4X |
Case Material | Valox* 364 |
Cat. No. | Description |
---|---|
2117XPEN | Chloride Analyzer with Protective Enclosure Package – includes 2117XP chloride analyzer with protective enclosure, chloride electrode (100025), reference electrode (100057), ATC probe (2100TP), chloride calibration standards kit (211740), CD user guide and options kit |
2117XP | Chloride Analyzer Instrument Only Package – includes 2117XP chloride analyzer with chloride electrode (100025), reference electrode (100057), ATC probe (2100TP), chloride calibration standards kit (211740), CD user guide and options kit |
211750XP | Chloride Consumables Kit – for one year operation, includes 6 x 1L formic acid reagent and 6 x 2 ft. diffusion tubing with O-rings (182011), chloride calibration standards kit (211740), chloride electrode (100025), reference electrode (100057), 4 oz. reference filling solution (100057F4), O-ring kit (2100OK), check valve (2100VC), box of pipette tips (204846-001), restriction tube assembly (2100RT) and inlet filter with gaskets (181170) |
2117XPEK | 2117XP Electrode Kit – includes chloride electrode (100025), reference electrode (100057) and 4 oz. reference electrode filling solution (100057F4) |
2117XPCAL | Chloride Calibration Kit with Carrying Case – includes 0.5 mL pipette (204847-001), box of pipette tips (204846-001), wash bottle, 2 oz. chloride standard 1 (296 ppm), 2 oz. chloride standard 2 (2946 ppm) and inlet filter |
2117XPSK | 2117XP Service Kit – includes electronics faceplate (2117XPEP), air pump assembly (2100PA), regulator assembly (2100RG), 2 electrode cables with gland assemblies for sensing and reference electrodes (2100EC), power supply assembly (2100PS) and fuse kit assembly (2100FK115 and 2100FK230) |
2117XPEP | 2117XP Electronics Faceplate |
211750XPF | Reagent-less Chloride Consumables Kit – for one year operation, includes 6 x 1L empty bottles for formic acid reagent, 6 x 2 ft. long diffusion tubing with O-rings (181060), chloride calibration standards kit (211740), chloride electrode (100025), reference electrode (100057), 4 oz. bottle reference filling solution (100057F4), O-ring kit (2100OK), check valve (2100VC), box of pipette tips (204846-001), restriction tube assembly (2100RT) and inlet filter with gaskets (181170) |
2117RBA | 2117XP Reagent Bottle Adapter |
2117XPG | Chloride Analyzer with Integral Grab Sampler Package – includes 2117XP chloride analyzer with integral grab sampler, chloride electrode (100025), reference electrode (100057), ATC probe (2100TP), chloride calibration standards kit (211740), CD user guide and options kit |
2117XPENG | Chloride Analyzer with Integral Grab Sampler and Protective Enclosure Package – includes 2117XP chloride analyzer with integral grab sampler and protective enclosure, chloride electrode (100025), reference electrode (100057), ATC probe (2100TP), chloride calibration standards kit (211740), CD user guide and options kit |